酒店结构化综合布线系统建设分析 酒店 综合布线 结构化 多网性 现代化星级酒店必须有信息化系统支撑其多种上层应用,结构化综合布线系统PDS作为计算机网络的基础物理平台,应为酒店信息化系统建设提供必要支撑;同时结构化综合布线系统也为酒店内部的模拟和数字语音系统、多媒体电子会议等信息传输提供必要的传输通道。建设良好的综合布线系统能适应各种各样的互联方案和建筑环境,并能应用于多种网络结构,同时能提供极其灵活的特性适应未来应用的变化。 酒店结构化综合布线系统一般可覆盖以下各方面应用功能: 涉及网络互联的计算机系统以及各类计算机外部设备等 涉及电话通信系统(如电话、传真、会议的控制站点设备等) 涉及酒店互动电视服务系统的传输链路 酒店作为日常人们外出公务和旅游时的居住环境;有时也作为临时的会议或活动举行场所;其各种服务功能齐全。因此星级酒店结构化综合布线系统在整体建设中具有不同于一般结构化综合布线系统的网络架构及布点原则等方面特点,体现了鲜明的商务特色及酒店特色。 酒店网络不但需要能支持如酒店资产和日常业务管理、前后台服务、商业、娱乐、POS消费、结算及办公自动化系统等酒店内外部管理的应用方面,还要求能支持如多媒体信息发布、酒店客房状态的实时管理、VOD互动电视点播及信息服务的数据传输、住店旅客的上网访问需求以及酒店无线网络覆盖等等方面的各项应用。 因此分析星级酒店网络的各种实际应用;酒店结构化综合布线布线系统具备以下主要应用特点: 酒店属于服务性行业,客人的入住率以及投诉率是酒店日常管理的重要一环,而电话语音通讯是直接展现在客人面前的设备系统,因此语音通1 叶予舜 二○一二年九月四日星期二
讯布线的作用至关重要 酒店客房楼层区域基本都使用酒店管理信息系统,对电话语音系统有各种特定功能需求 星级酒店客房卫生间内一般布置有电话分机,且与客房电话为同一分机号码 星级酒店一般配置VOD视频点播系统,综合布线系统需与之配套 酒店内部大堂内有前台、电话亭、大堂经理接待台等服务设施,对应的电话语音、数据网络布线均应到位 星级酒店内设置有会议室、餐厅、休闲场所、健身场所、购物场所等各种配套设施,这些设施都需根据各自特点布置综合布线系统 要防止非法人员从酒店客房内入侵酒店内部管理系统,造成不必要损失 现今国际上不少酒店管理集团都有自己的计算机网络和电话语音通讯的综合布线系统设计规范,在进行此类酒店宾馆的布线设计时需参考对应的特定规范 按照酒店综合布线系统的应用特点,其信息点布置也具有鲜明特点: 信息点需求量大:由于入住客户成分比较复杂,对于计算机网络接入的需求比较大 语音点可串联:酒店内部大多为客房楼层区域,要求卫生间和客房内的电话可同时振铃,因此可将客房床头、书桌等部位以及卫生间的电话串联在一起,以节省建设费用 安装位置复杂:酒店内人流较复杂,在信息点安装位置设计上不但需要考虑大多数人员的使用,还需为儿童、残障人士等特殊人员考虑 以五星级商务酒店综合布线系统为例分析,对信息点布置有如下设计内容: 地下一、二层为地下车库,在车库的2个一进一出的出入口,设置数据点和语音点,用于一卡通车辆管理系统联网和管理人员对外联系 在地下一层的消控中心机房内布置数据点和语音点,用于建立安保、BA、广播、一卡通等系统联网 在酒店一层大堂,布置有酒店总前台,需要配备一定数量的电话点和数2 叶予舜 二○一二年九月四日星期二
据点;此外酒店一层具备ATM自动取款机、公用电话间、多媒体信息导航和信息发布系统等,因此在对应位置也需要布置相应数据点或语音点 在该星级商务酒店一层还布置有精品购物店、特色酒吧等设施,设计在该类区域特别是内部收银区域布置数据点和语音点 酒店二层是中餐高档包房,配备语音点,用于服务员与服务台或厨房联系点菜事宜等 在酒店二层还布置有容量500人的多功能大宴会厅,内设活动门隔板,可以灵活分隔或合并使用,主要用于婚宴、新闻发布会、各种涉外商务会议的举行,需要在内部配置足够数量的数据点和电话点,满足网络和语音通讯需求 三层主要为会议层,针对会议室内部要建设多媒体电子会议系统的要求,在各个会议室内布置足够数量的数据点和语音点 对于酒店内部的部门办公区域,设计为每位普通工作人员按照每个工位布置1个数据点和1个语音点,对于经理、总监等领导办公室布置至少2个以上数据点和2个以上语音点 该商务型酒店七层以上为客房层,主要分为以下几类: 标准客房:每间布置3个数据点和1个语音点,外加2个串联语音点;2个数据点分别布置在床边和书桌旁,另外1个数据点供酒店客房区建设的VOD电视点播系统接入机顶盒使用;1个语音点布置在客房茶几座位旁边位置,2个串联语音点设计布置在床头柜边和卫生间内,用于并联电话使用 套房:为卧室和客厅双间,设计信息点布置按照两间标准客房配置;即包括两套2个数据点和3个语音点(2个串联语音点)设置,外加1个机顶盒接入数据点 总统套房和豪华套房:酒店内有少部分总统套房和豪华套房,为多间结构,基本都按多套标准客房的信息点配置来布置 客房卫生间内语音点设计配备防水溅罩,并确保插座内的插针位于插座的上部,以避免水蒸气凝露造成整个并联电话线路短路导致电话不通 3 叶予舜 二○一二年九月四日星期二
酒店的客梯和货运电梯对酒店服务质量的体现至关重要,在电梯机房内布置数据点和语音点,一方面可以实现设备联网,另一方面可让电梯机房内具有分机电话使用 作为五星级商务酒店,应提供丰富的无线上网功能,作为有线网络的有效补充;现设计在一层的大堂和特色酒吧、二层的餐厅区域、四层的休闲娱乐场所以及顶层二十八层的云顶会所等处布置无线接入数据点 根据对该商务酒店的应用分析和信息点布置设计,整个酒店结构化综合布线网络应为一个多网性结构,分为以下几部分: I.酒店管理网 支持酒店管理软件、信息查询软件、电子公告系统及卡管理系统等网络应用,主要为酒店管理方面应用,传输带宽为百兆到桌面,实际传输速度没有严格要求。 II.客房信息网 支持客房管理信息方面的网络应用,主要是对整个酒店的所有客房状态进行实时管理。传输带宽为百兆到桌面,实际传输速度只要直观感觉不慢即可。 III.客房Internet网 主要是给住店旅客的上网访问及互相之间的数据传送使用,传输带宽应在10Mbps以上。 IV.客房信息服务网 支持酒店互动电视及信息服务系统(VOD)的数据传送,以提高酒店的服务质量,传输带宽常定为以上。 V.无线网 为酒店提供补充的无线上网功能,用于接入无线网络AP点使用。 4 叶予舜 二○一二年九月四日星期二
VI.语音网 该酒店建立一套的语音通讯布线网络,通过集中程控交换机系统和酒店管理信息平台划分针对酒店公共区域、客房以及酒店内部管理办公区域的不同应用。 根据以上网络应用的划分,整个酒店结构化综合布线系统将分成四个独立的物理网络: 酒店管理网:通过VLAN技术可逻辑分隔为酒店管理网和客房信息网 客房管理网:通过VLAN技术可逻辑分隔为客房Internet网和无线网 客房信息服务网:从带宽分析要求,客房信息服务网络设计独立建设 语音网:独立建设一套语音通讯布线网络 酒店结构化综合布线系统在整体系统结构上严格遵照有关综合布线系统设计的标准规范,体现标准化模块化原则;一般从系统结构上分为工作区子系统、水平布线子系统、垂直主干子系统、管理间子系统、设备间子系统和建筑群子系统(酒店结构化综合布线系统一般为单体建筑结构,无建筑群子系统)。该五星级商务酒店布线系统采用国际标准的星级拓扑,分为两级结构:接入层和核心汇聚层: I.工作区子系统 工作区子系统是用户的最终接入区,主要包括信息插座、信息面板、终端跳接线等部分。 信息终端插座:采用超五类非屏蔽模块,可灵巧吻合地连接至插座面板、桌面安装盒及模块化配线架上;选择45度斜角安装方式,便于客房有网络需求的住客频繁插拔跳接线方便 信息面板安装方式:由于酒店内部建筑结构情况各异,空间使用情况也各异,信息面板安装有多种方式,设计采用了以下几种方式: 墙面安装:大部分区域都采用墙面86盒信息面板安装方式 隔板安装:酒店的工作人员办公区域有大开间隔板分隔,此处采用隔板上信息面板安装方式 5 叶予舜 二○一二年九月四日星期二
地面安装:领导办公室、会议室、宴会厅等处采用金属制地面插座安装方式 吊顶安装:无线网信息点采用吊顶安装方式 对于五星级商务型酒店来说,信息点安装还有几个需要特别注意的地方: 为方便入住宾客上网便利,客房内数据点安装高度应在书桌桌面以上 客房卫生间内电话信息点安装高度一般为80厘米,以方便客人如厕时使用电话 为方便残疾人及儿童在大堂使用公用电话,对应区域应有部分语音点安装高度不得超过80厘米 II.水平布线子系统 水平布线子系统是将垂直干线子系统线路延伸至用户工作区,端接在信息插座上。水平布线子系统主要包括水平走线、水平线缆选型等部分。 为了适合结构化综合布线设计要求,该酒店布线系统的语音水平布线和数据水平布线统一采用低烟无卤超五类四对非屏蔽线缆。设计水平线缆从楼层配线间出发,通过楼层弱电井道到达各楼层,进入楼层水平桥架,然后在各个用户工作区通过管道引至信息插座,端接在信息插座上。 由于在酒店客房内部有串联语音点要求,因此客房内的语音水平布线入户后先接入客房内卫生间,再跳接至卧室或客厅房间内;因此对于客房内语音水平入户布线,只需按照对应每个非串联语音点的数量布置语音水平线缆即可。 III.垂直主干子系统 干线子系统提供建筑物的干线电缆电路,把各个楼层配线间链接至设备间子系统,直至传送到最终接入接口,再通往外部网络。干线子系统主要包括供各类干线(铜缆和光缆)走线用的竖向或横向通道、干线选型等部分。 干线的水平通道主要是指用于敷设干线水平走线的水平金属桥架;竖向通道为酒店楼层弱电管笼和结构预留洞。 6 叶予舜 二○一二年九月四日星期二
根据前面的网络应用分析,该酒店的语音主干线缆采用低烟无卤三类非屏蔽大对数铜缆;数据主干线缆采用低烟无卤6芯多模光纤;即可满足酒店的网络带宽要求。 语音电话主干与每根语音水平线缆端接一对线,但必须留有一定余量;对于客房区,由于客房内有串联语音点,所以设计不需为客房考虑串联语音点的语音主干端接预留。 由于酒店数据网络采用酒店管理网、客房管理网、客房信息服务网络各自物理隔离的布线系统,因此要考虑各自的数据主干冗余,因此数据主干到每个独立物理布线网络的楼层配线间各采用1根低烟无卤6芯多模光纤链接。 IV.管理间子系统 该商务型酒店的布线网络结构为两级结构,则管理间子系统即指各楼层配线间IDF,作为接入层使用。它的作用是将干线子系统和水平布线子系统链接起来,一般包括配线架、跳线系统、光纤接续单元及配件等。主要做如下配置设计: 语音主干端配线架采用110卡接式语音配架 数据主干端配线架采用光纤配线架包括配架、面板、耦合器等 水平端配线架统一采用超五类非屏蔽块接式配架,能便于实现在楼层配线间内需要的语音点和数据点进行灵活互换使用 酒店为主裙楼结构,四层以下为裙楼,楼层面积较大;而五层以上为主楼,楼层面积较小,信息点布置比较集中;根据各区域信息点分布及楼层情况,对楼层配线间IDF分布进行如下设计布置: 四层以下裙楼部分在对应楼层设置2个或多个楼层配线间IDF,实现楼层分区管理 五层以上以两层或多层设置一个楼层配线间IDF,便于实现集中管理 按照酒店布线系统的多网性结构特点优化布置IDF: 酒店管理网主要覆盖酒店六层以下区域,基本可以独立设置对应IDF 客房管理网和客房信息服务网主要都是覆盖七层以上区域,且信息7 叶予舜 二○一二年九月四日星期二
点布置情况大致相同,可以将IDF进行优化合并 语音网络为整套独立网络,且大部和数据信息点一一对应布置,因此语音网楼层IDF可与前述数据网络的楼层IDF对应合并设置 在楼层配线间IDF内,一般设计将系统配线设备和其它网络设备等安装在标准机柜中,这样可大大加强安全性和稳定性,并改善系统供电、散热和工作环境。机柜必须单独布线至接地体,接地体应与建筑的整个接地系统相连。 V.设备间子系统 该酒店综合布线的设备间子系统包括电话总配线间与网络总配线间,即为系统汇聚层;设置在地下一层。各个管理间子系统通过干线子系统星型链接至此,同时也作为和外部语音以及数据接入的链接桥梁。 电话总配线间包括有电信进线的配线管理、程控交换机核心设备、酒店内电话干线的配线管理、跳线管理等。电信进线从酒店外部引入电话总配线间,端接在进线配线架上,然后再跳接到程控交换机;内部从管理间子系统来的电话干线也是在电话总配线间配线后,再跳接至交换机分机线配线架。在电话总配线间内由于配线规模较大,可以采用墙装型配线架以节省空间;同时注意要预留足够的酒店直线电话端接点。 网络总配线间和电话总配线间情况大致相同:包括运营商网络接入进线的配线管理、网络核心路由设备、酒店内数据干线的配线管理等。外部网络接入进线从酒店外引入网络总配线间,端接在进线配线架上,然后再跳接到网络核心路由设备;内部从管理间子系统来的数据干线也是在网络总配线间配线后,再跳接至网络核心路由设备。根据实际的实施要求和便于集中管理,酒店内设置独立的弱电进线机房,外部电信进线和运营商网络接入进线在进线机房统一配线后,再分别跳接至电话总配线间和网络总配线间处。 根据上述针对酒店结构化综合布线系统的建设分析,该系统建设是一项综合工程;酒店结构化综合布线系统建设既要遵照统一的结构化综合布线规范,也要8 叶予舜 二○一二年九月四日星期二
充分结合酒店本身网络应用上的特殊性,灵活而又严格地进行标准化设计。 9 叶予舜 二○一二年九月四日星期二
智能化系统方案 酒店 综合布线 方 案 书 第1页
智能化系统方案 第一章 项目概述 前言: 建筑弱电工程设计的出发点,应以建筑及周围环境为平台,配置各功能系统,为人们提供一个投资合理、高效、舒适、便利的环境空间,以适应当前现代办公休闲的需要。从具体设计上,应从建筑构造的实际性质出发,充分考虑业主和使用者的各种功能要求,使设计能在总体结构上尽量现代化,技术上先进实用,经济上合理,同时需考虑各系统的可兼容性和扩展性。设计依据遵循: 《建筑与建筑群综合布线系统工程设计规范》 GB/750311-2000 《民用建筑电器设计规范》JGJ/T 16-92 《智能建筑设计标准》 GB/T 50314-2000 《千兆以太网标准》 IEEE80X、3AB、80X、32 《有线电视系统工程技术规范》GB50200-94 《民用闭路监控电视系统工程技术规范》GB50198-90 《建筑物防雷设计规范》GB50057-2000 (一)项目概况: 根据“酒店”的《规划平面布置图》。 (二)功能要求 a.系统的方案设计与当前科学技术高速发展的潮流相吻合,系统总体结构定位合理,确保能够适应未来技术发展变化的应用和扩展; b.系统设计首先以实用为第一原则。在符合当前实际应用需要的前提下,合理平衡系统的经济性和先进性,避免片面追求先进性而脱离实际或片面追求经济性而损害系统智能化的功能; c.系统建成后,能够保持24小时全天候连续工作。局部故障绝对不能影响整个系统的运作,系统的关键部件宜考虑容错和备份; d.充分考虑系统的极端安全性,保证系统运行安全可靠。既能符合业主、国家或国际的相关安全标准和规范的要求,又要确保系统内部的数据信息在传输、存储及使用过程中安全可靠; e.在系统或设备选型中,以现有成熟的设备和系统为首选对象,以智能化总体目标为方向,局部服从全局、全局高度平衡,力求使系统在初次投入和整个运行周期内可获得最优的性能/价格比,完美实现业主建设智能化系统的初衷; f.由于系统监视和控制的内容广泛,涉及各类性质的对象,系统包含的设备品种繁多且复杂,同时安装位置分散,因此,建成后,系统要求具有很强的可维护性和易维护性,既要做到有效减少工程管理 第2页
智能化系统方案 维护人员,又要降低维护工作的强度和维护运行开支; g.在系统设计中遵循国家和国际各相关的标准及协议,能够兼容不同厂家、不同协议的系统或设备。系统采用符合工业标准的操作系统,并针对各符合国际主流工业标准的第三方系统或设备提供开放接口,以便用户以后能根据实际需要进行二次开发。 (三)总体设计原则要求 a.建设目标 应用现代化技术和科技产品,提高科技含量,使其具备升值空间。建成语音、数字、图像传输的高速通道,提高办公效率;建成向数字化发展的平台,适应高速发展的信息产业;使其成为一个实用、高效、先进的智能建筑群。 b.系统配置原则 系统设计和工程实施管理中遵循如下原则: 可行性和适应性 实用性和经济性 先进性和成熟性 开放性和标准性 可靠性和稳定性 安全性和保密性 可扩展性和易维护性 对于XXX工业园区弱电系统工程的规划设计,严格遵循如下设计依据: 《建筑智能化系统工程设计管理暂行规定》建设部(1997-290); 《中华人民共和国安全行业标准》(GAT70-94, GAT75-94); 《智能建筑设计标准》(GB/T50314-2000); 《智能建筑设计规范》(DBJ-08-47-95); 《民用建筑电器设计规范》(GBJ/T1-92); 《民用建筑电气设计规范》(GBJ/T16-92); 《电气防盗报警器通用技术条件》(GB/12663-90); 《安全防范工程程序与要求》(GA/T75-94); 《防盗报警控制器设计规范》(GB/T75-94); 《建筑设计防火规范》(GBT16-87); 《建筑及建筑群综合布线系统国家标准》(ISO/IEC11801); 《商业建筑综合布线标准(修订版)》(EIA/TIA-568B); 第3页
智能化系统方案 《建筑及建筑群综合布线系统设计规范》(GB/T50311-2000); 《建筑及建筑群综合布线系统工程及验收规范》(GB/T50311-2000); 《商业建筑电信通道及空间标准》(EIA/TIA-569); 《智能建筑工程质量验收规范》(GB50307-2002); 《信息技术互连国际标准》(ISQ/IEC11801-95); 《通信布线系统信息技术欧洲标准》(EN50173); 《工业企业通信设计规范》(GBJ42-81); 《电子计算机机房设计规范》GB50174-93; 《电子计算机机房施工及验收规范》SJ/T30003-93; 《电气装置安装工程电气设备交接实验标准》 GB50150-91; 《电气装置安装施工及验收规范》GBJ232-90,92; 《工业与民用供电系统设计规范》GBJ52-83; 《工业与民用电力装置的接地设计规范》GBJ65-83; 《物业管理IS09002》GB/T19002-1994; 《综合布线系统电气特性通用测试方法》YD/1013; 相关国际标准,国家规范,地方规定。 c.设计要求: 本次为新锦江酒店工程弱电智能化系统工程提供方案设计、施工图纸深化设计。 提供如下内容: 1. 提供系统总图、各子系统的系统图及能有助于阐明系统设计思路和系统功能的描述图等; 2. 详细阐述该方案中各子系统的设计原则、依据、功能、性能及所设计系统的技术先进性和合理性; 3. 详细阐明各子系统的网络构成方式,集成系统的网络结构、功能及其通讯标准和各子系统之间的相互关系; 4. 提供图片说明各子系统,集成系统软件的操作界面和应用环境。 (四)系统组成 根据系统方案的设计思想 ,本设计方案由以下各个系统组成: (1)结构化综合布线系统;; 第4页
智能化系统方案 第二章 综合管道布线系统 (一)结构化综合布线系统 1、概 述 综合布线系统是建筑物或建筑群内的信息传输系统。是弱电系统数据和语音传递的基本通道。它使语音和数据通信设备、交换设备、信息管理系统及设备控制系统、安全系统彼此相连,也使这些设备与外部通信网络相连接。它包括建筑物到外部网络或电话局线路上的连线、与工作区的话音或数据终端之间的所有电缆及相关联的布线部件。布线系统由不同系列的部件组成,其中包括:传输介质、线路管理硬件、连接器、插座、插头、适配器、传输电子线路、电器保护设备和支持硬件。为了有效地利用这些设备,并让它们发挥最大的效果,大楼将采用综合布线系统实现电话和计算机系统资源的综合利用。本方案在满足用户需求的前提下,重点考虑今后的系统扩充、可靠性、易维护、易管理等问题。 2、综合布线系统需求分析 TM康宝综合布线智能系统的结构化综合布线系统(PREMISE CABLING SYSTEM)的建设是一个综合的、统一的信息系统工程,满足当前和未来网络通讯技术的发展需要,实现综合语音、数据和图像为一体的信息传输。本方案将提供全面、完整和可扩展性强的解决方案,方案在设计中充分理解用户对智能化工程建设的要求,对系统现在以及将来的应用及连接需求进行综合分析,在系统需要扩容和扩展而进行下一步实施时,可以方便并且平滑的实现。 在康宝综合布线系统的设计规划上,我们按照设计院提供的平面图、系统图和业主对布线系统应用及营运的基本要求,并根据综合布线国际及国内标准的要求,结合本公司的系统专业经验,为用户提供保证现在及未来应用的高速网络平台。该综合布线系统建设主要满足语音、数据及视频的应用需求,为高带宽应用程序提供完全的端到端布线解决方案,具有很强的超前性,适用于未来网络的扩展及升级,减少维护费用。 根据业主的基本设计要求,此次综合布线系统的核心要求如下: 满足相关的国际标准和国家标准; 能够支持各种计算机网络设备、电话系统及视频多媒体系统; 具有先进性、可靠性、可互换性和可扩充性; 垂直数据主干采用光纤作为数据主干; 语音主干采用三类大对数电缆; 本大楼综合布线系统是一个模块化、灵活性较高的智能化布线系统,通过延伸到每个区域单元的信 第5页
智能化系统方案 息点,将电话、电脑、网络设备、通讯设备与管理设备连接为一个整体,高速传输语音、数据、图像,从而为内部管理者和使用者提供综合性资讯服务。 为了满足业主的需求,本综合布线系统方案设计遵循以下原则: 实用性:满足园区的电话通信系统、办公自动化和计算机网络系统对布线的需求。能兼容话音、数据、图象的传输,并可于外部网络连接。 灵活性:为开放式结构,能支持话音及多种计算机数据系统,在应用上能支持视频会议、多媒体等系统的需要。即用户任一信息点能够连接不同类型的设备,如计算机、打印机、终端或电话、传真机。 模块化:布线系统中,除去固定在建筑物内的线缆外,其余所有的接插件都是积木式的标准件,以方便管理和使用; 扩充性:布线系统是可扩充的,以便将来有更大的发展时,很容易将设备扩展进去。本方案采用树状星型结构,以支持目前和将来各种网络的应用。通过跳线和不同的网络设备,可以实现各种不同逻辑拓扑结构的网络,系统扩充时仅需在相关的“树叉”上添入新的线缆就可以实现; 标准性:满足最新、最高的布线系统标准(如国家标准:CECS 72:97和CECS 89:97、国际标准:ISO/IEC 11801、欧洲标准:EN50173等),本方案要求可满足目前超五类技术标准的要求; 可靠性:在设计中充分考虑到系统的长期可靠性。本方案从力的作用方向出发,以具有高可靠性的机柜型配线系统为核心,添入了使线缆不会对模块产生拉力的线缆管理器和不会对RJ45头产生拉力的跳线管理器,努力提高系统可靠性和安全性; 经济性:在满足应用要求的基础上,尽可能降低造价,实现最优的性能价格比。 3、系统设计 本综合布线系统将针对电话系统和计算机网络系统对线缆的要求进行设计。根据国际布线标准EIA/TIA568标准和ISO/IEC11801 的设计原则,该大楼的布线系统将由工作区子系统、水平子系统、设备间子系统、垂直主干子系统系统、管理子系统及建筑群子系统六个部分构成。在本方案中充分考虑了布线系统的高度可靠性、高速率传输特性及可扩充性。 第6页
智能化系统方案 水平布线子系统 垂直干线子系统 U N I V E R S I T Y工作区子系统 管理间子系统 PB 建筑群子系统 设备间子系统 水平线槽(内穿水平线或光纤) 吊顶 预埋铁管 信息插座(包括 面板、模块和铁由电话、计算办公间隔盒) 机引出的 RJ45接头 4、 解决方案 综合布线系统是一个能够支持任何用户选择的语音、数据、多媒体等应用的建筑物通信布线系统。能够支持语音、图像、数据等各种信号的传输,支持各种传输载体及多用户多类型产品和高速网络的应 第7页
智能化系统方案 用,如果在建楼时已经充分考虑了信息系统的使用需求,那么在大楼建成后,一方面能使办公人员获得极其良好的工作环境,大大提高工作效率,而且整个系统运行维护的经济性也会大大提高。布线系统是与建筑、装潢等方面密切相关的,因此,在本方案书中,将涉及多方面的因素,并对布线工程的总体规划和结构提出自己的设计方案。 为了能够顺利地完成该项目的综合布线系统设计和实施工作,在本方案书中,康宝综合布线智能系统(台湾)有限公司将根据本项目的实际情况,充分发挥本公司在综合布线系统设计和施工方面的专业技术和经验,以及在布线工程中的综合协调能力,向业主提出完整的系统解决方案。 康宝综合布线智能系统的建设目标是完善园区综合办公大楼及生产厂房一套完整的通讯管理控制系统,根据客户需求及本项目的应用特点,该综合布线系统分以下几大子系统建设: 工作区子系统 工作区是办公室、写字间、作业间、技术室、机房等需要电话、计算机终端等设施的区域和相应设备的统称,一个独立的需要设置终端设备的区域宜划分为一个工作区,工作区子系统由设在各办公室内的信息插座、跳线(连接信息插座至终端设备之间的线缆)、适配器(信号转换器)构成,在该区域配置一个双孔面板和信息插座用于端接从管理区配线架到工作区水平线缆,提供即插即用接口,当用户需要连接Internet时,只需用一条UTP跳线从信息插座连接到用户网络交换即可。一个工作区的服务面积可按5-10平方米估算,或按照不同的应用场合调整面积的大小。对于工作区的服务面积,一般办公室约为5-10平方米,机房则比较复杂,网管中心、总调度室等有人值守的场所与办公室类似,设备机房,按电信大楼的经验,约为20-30平方米。国内规范规定工作区的服务面积为5-10平方米的范围,设计时应根据不同的应用场合进行选定。TO 网络跳线 工作区子系统中所需要的结构化布线产品介绍: TM 本产品名:PREMISE CABLING SYSTEM超五类非屏蔽信息模块 第8页
智能化系统方案 超五类模块是根据国际标准TIA/EIA-568-A-5设计制造的性能优异的插座模块 模块的电路板和簧片采用专利的平衡技术 衰减、回损和近端、远端串扰方面的性能超过超五类标准的要求 传输带宽超过150MHZ 安装全面兼容COMBO各类面板和快速安装板 所有材料具有25年的性能保证 美国UL-实验室认证 本产品名:PREMISE CABLING TMSYSTEM高级系列面板 COMBO国际面板专为COMBO系列模块而设计,有单孔、双孔、三孔、四孔可供选择 亚光磨砂设计更符合现代室内装饰的要求,与标准的86cm暗盒相兼容。可更换多组颜色防尘盖,与配线架颜色相对应,便于色彩管理 本产品名:超五类非屏蔽跳线 ·颜色齐全,完全满足工程布线机房及用户端的管理 各种长度:1m/ 采用50Micro镀金之水晶头RJ45 布线顺序与连续性100%经过工厂FluckDSP4300测试 接线方式:568B-568B 水平子系统 水平布线子系统由工作区的信息插座、信息插座至楼层配线设备的配线电缆或光缆、楼层配线设备和跳线等组成。 水平子系统电缆 第9页
智能化系统方案 水平子系统设计原则及建议: 数据水平区线缆全部采用4对超五类非屏蔽双绞线,支持100MHz带宽,能满足数据、图形、影像等多媒体信息传输要求,可以支持100Mbps的传输要求 语音水平区线缆全部采用2对三类电缆,满足电话、传真等传输需求 每一个信息插座到管理间都用水平线缆连接。从管理间出来的每一根 4对双绞线都不超过90m,且遵循TIA/EIA 568-B《民用建筑通信标准》 水平子系统中所需要的结构化布线产品介绍: TM 本产品名:PREMISE CABLING SYSTEM超五类线缆 超出ANSI/TIA/EIA-568中对超5类的要求 最大带宽和ACR余量满足关键任务或噪音环境 用于同步并行传输协议和优化平均传输参数 最小的尺寸更易于紧密安装 所有材料具有25年的性能保证 电缆长度递减标记减少浪费 与电话的第一、二线匹配,易于安装和转换 按ANSI/TIA/EIA-568-A色谱编码 CMR级,UL认证 TM 本产品名:PREMISE CABLING SYSTEM三类两对四芯语音线缆 超出ANSI/TIA/EIA-568中对三类的要求 最大带宽和ACR余量满足关键任务或噪音环境 用于同步并行传输协议和优化平均传输参数 最小的尺寸更易于紧密安装 平均轴向转换损损耗控制低电磁干扰和抗噪音 绝缘一致性提供了更低的传输延时 小的外径尺寸,减少安装中电缆的扭曲或打结 垂直主干子系统 干线子系统应由设备间的建筑物配线设备和跳线以及设备间至各楼层交接间的干线电缆组成,提供 第10页
智能化系统方案 建筑物的干线电缆路由。该子系统由垂直主干电缆或光缆组成。相当于电缆配线系统中干线电缆。建筑物综合布线系统中的干线子系统是建筑物内的主馈电缆,它的主要功能是把来自各配线间和远程通信服务接线间的信号传送到设备间,直至传送到最终接口,再通往外部网部。干线子系统包括: 1)干线或远程通信接线间和设备间之间的竖向横向的电缆走线用的通道。 2)设备间和网络接口之间的连接电缆或设备间与建筑群子系统各设施间的电缆。 3)干线接线间与各远程通信接线间之间的连接电缆 4)主设备间和计算机主机房之间的干线电缆。 干 线 电 缆 P 设 备 间 垂直子系统设计思路及原则: XXX中心及设计中心从XXX中心中心机房引用室外6芯多模光纤至各楼分设备间为数据主干,作 为用户上网、视频及多媒体等通讯需求传输主干。 XXX中心及设计中心从XXX中心中心机房语音主干采用三类100对大对数电缆,作 为用户电话、传真等通讯需求传输主干。 垂直主干子系统中所需要的结构化布线产品介绍: TM 本产品名:PREMISE CABLING SYSTEM三类主干大对数电缆 COMBO 100Ω三类主干电缆属于大对数阻燃级电缆系列,它满足和超过ANSI/TIA/EIA/-568A-A和CSA 3类传输特性的规范。3类大 第11页
智能化系统方案 对数UTP,硬铜导线电缆芯,PVC与LSZH-FR(低烟、无氯素、阻燃护套)。与CSAT-529,商业建筑物通讯电缆系统设计标准保持一致。 超出ANSI/TIA/EIA-568-A中对3类的要求 最大带宽和ACR余量满足关键任务或噪音环境 用于同步并行传输协议和优化平均传输参数 最小的尺寸更易于紧密安装 所有材料具有25年的性能保证 电缆长度递减标记减少浪费 与电话的第一、二线匹配,易于安装和转换 按ANSI/TIA/EIA-568-A色谱编码 CMR级,UL认证 TM 本产品名:PREMISE CABLING SYSTEM多模室内光纤 由于此项目对信息传输要求较高,因此我们建议楼内采用6芯的室内多模光纤作为数据主干。6芯多模光缆具有极大的传输带宽和无与伦比的传输质量,提供3个传输通道,既提供了充分的容错冗余,又保证了主干网上的数据传输的质量和速率,而且为将来其他独立于计算机网络的其他高速传输应用提供了实用的传输连接,这对于大楼内的高速事务处理一定会带来极大的方便。多模光纤其优点有:光耦合率高,纤芯对准要求相对较宽松。当计算机数据传输距离超过100米时,用光纤作为主干将是最佳选择。并具有大对数电缆无法比拟的高带宽和高保密性、抗干扰性。随着计算机网络和光纤技术的发展,光纤的应用愈来愈广泛。光纤的数据传输速率可达1Gbps以上,适应计算机网络的发展,具有先进性和超前性。 Combo室内光纤系列产品具有低传输损耗值和高带宽传输能力,是传输高速数据的最佳传输介质。它能最大程度的提供数据的保密性和完整性,且不受电磁、雷电干扰,并支持未来的高速数据传输和多媒体技术。 全绝缘型 标准绿色护套(阻燃、低烟、无卤素) 优化设计的缓冲层具有很强的附着力,保证接头可靠、持久的 连接 793/2 及FDDI规范 50/125μm光纤符合IEC 793/2及 FDDI规范 每芯带有彩色编码缓冲 第12页
智能化系统方案 在本建议书中,垂直主干采用星型结构,从主机房MDF以点到点的形式铺设语音及数据主干到各个楼层配线间IDF。选择垂直子系统拓扑结构为星型拓扑结构,这是因为星型拓扑结构: 1)便于管理,星型拓扑结构的所有通信都要经过中心节点来支配,所以维护管里比较方便。 2)便于重新配置。用户可以在楼层配线架上任意增加、删除或移动、互换某个或某些信息插座,而且 仅仅涉及它们所连接的终端设备。 3)便于故障隔离与检测。由于各信息点都连接到楼层配线架,相互之间保持相当大的独立性,因此可 以方便地检测故障点,并清除。 4) 便于系统的分段、级连与扩充。 管理子系统 管理间子系统主要功能是实现配线管理,由交连、互连和输入/输出组成管理点为连接其它子系统提供连接手段。交连和互连允许将通讯线路定位或重定位到建筑物的不同部分,以便能更容易地管理通信线路。使在移动终端设备时能方便地进行插拔。 配线间是各管理子系统的安装场所,用于将连接至工作区的水平线缆与从主设备间引出的垂直线缆相连接。对于信息点不是很多,使用功能又近似的楼层,为便于管理,可共用一个子配线间;对于信息点较多的楼层应在该层单独设立配线间。配线间的位置宜选在距弱电竖井旁附近的房间内,用于安装机柜、配线架和网络通讯设备。 管理是针对设备间、交接间和工作区的配线设备、缆线、信息插座等设施,按一定的模式进行标识和记录的规定,内容包括管理方式、标识、色标、交叉连接等。综合布线系统使用三种标记:电缆标记、区域标记和接插件标记。其中接插件标记最常用,这些内容的实施,将给布线系统的维护和管理带来很大的方便。 管理子系统 第13页
智能化系统方案 管理间子系统设计思路及原则: 光纤采用12/24口机架式光纤配线架,用于端接从楼层IDF至MDF的光纤主干,当某一对光纤需要投入使用时,只需将与之对应的光纤通过光纤跳线连接到设备光纤端口即可,方便于日后系统的扩充、管理和维护。 数据水平线缆采用CAT5E 24口机架式配线架,用于端接从工作区到管理区的水平电缆。各配线间水平系统配线架采用可随意搭配不同功能模块(语音、数据、光纤)的配线架, 语音水平线缆采用110型100对机架式配线架,用于端接从工作区到管理区的水平电缆。 管理间子系统中所需要的结构化布线产品: 本产品名:COMBO超五类19”机架式24口非屏蔽配线架 后置式理线架,便于线缆的维护,以及增加线缆的弯曲半径 可更换式彩色框架与面板防尘盖相对应,可以更加方便的实现色彩管理 24口、48口型配置提供更大的灵活性及机架式安装 彩色标识,简化线路端接 坚固易于安装的设计 ·兼容各种标准机柜、机架和墙装拖架 美国实验室认证 本产品名:COMBO水平槽型理线器 更耐用和容易安装 增大的电缆前后穿通孔 旋开式盖板设计,理线更方便快捷,全鲷材质,长久不生锈,不会损伤跳线 容纳 24 至 72 根 UTP 电缆 本产品名:19”槽型理线架 安装在标准EIA 19英寸机架中 本产品名:机架式光纤收容箱、托盘、抽屉 COMBO提供光缆配线箱是新型、改良、经济的光缆布线产品,用于对不良环境中光纤端接与拼接的保护 有壁挂式8口和机架式12口、24口和48口规格 可选择安装ST、SC、FC等多规格的耦合器 第14页
智能化系统方案 赠送光纤熔接盘,以及附件,以便熔接施工 本产品名:光纤跳线 – 多模 多模和单模 9/125um , 50/125 和 um 型号 插入损耗低 回波损耗大 温度稳定性好 重复性好 互换性能好 本产品名:110型机架式配线架 110配线架是硬塑料的带标识组件,用于端接110连接块前的电缆聚集和对齐 110配线架连接可与22至26AWG之间兼容,可与4对及5对连接块配套使用,他们是专门用于简化数据电缆的安装 基座上较深的通道及线槽,使线缆能够紧靠端接点,这些连接块与其它已有的110交叉连接系统兼容 满足或优于ANSI/TIA/EIA568A的语音系统传输标准,完全符合T568A和T568B的线序 便于装在背板上,适用于在设备间内的大规模语音配线架 本产品名:110型19”机架式理线架 线缆管理槽置于配线架之间,用于水平束缚跳线和电缆 管理区配线间或设备间的配线区域,它采用交连或互连等方式,管理主干干子系统和水平子系统的线缆。管理点为连接其他子系统提供连接手段。交连和互连允许你将通信线路定位或重定位到建筑物的不通部分,以便更容易地管理通信线路。语音和数据全部采用模块化配线架,使语音和数据信息点可以互换及更换使用,能充分体现布线系统的灵活性,通过卡接或插接式跳线,交叉连接允许你将端接在配线架一端的通信线路与端接于另一端配线架上的线路相连。插入线为重新安排线路提供一种简易的方法,而且不需要安装跨接线时使用的专用工具。配线间的位置在弱电竖井内。配线间用于安装配线架和安装计算机网络通讯设备。 在设计中对楼层配线间和中心机房使用了相同的设备,这也使得整个系统管理维护起来更加的方便。主要的设备介绍如下: 第15页
智能化系统方案 本设计中,各配线间的连接设备全部安装于19英寸标准机柜内。其中数据主干管理全部采用COMBO 24/12口ST 光纤配线架,该光纤配线架高度为1U,为全模块化设计,可以随时更换和扩充,这样也是今后在维护过程中成本大大降低。 光纤连接设备统一采用COMBO 24/12 口机架式光纤跳线盘,高度为1U。该跳线盘使用塑料制造,轻巧而牢固,便于安装;模块化设计的适配器面板支持ST、SC、双口SC、MT-RJ、LC等连接标准;滑动式箱体、集中式的光纤管理,同时满足端接或熔接作。 设备间子系统 设备间是在每一幢大楼的适当地点设置电信设备和计算机网络设备,以及建筑物配线设备,进行网络管理的场所,对于综合布线工程设计,设备间主要安装建筑配线设备,电话、计算机等各种主机设备及引入设备可合装在一起。 设备间子系统完成公用系统设备的各种不同设备的互连,由设备间中的跳线、连接器和相关支撑硬件、机柜、配线箱等组成。设备间子系统把中继线交叉处、布线交叉连接处接连到应用系统上。由设备间的电缆、连接器和相关支撑硬件组成,把公用系统的各种不同设备互连起来。 设备导线 干线电缆 布线交叉连接处 系统公用设备 设备间子系统设计思路及原则: 在三层设立大楼园区MDF中心机房,作为计算机网络系统的中央管理控制中心,并管理整个园区 所有水平信息点 在三层弱电井道设置一个IDF,用于管理所有水平信息点,通过6芯多模光纤和100对大对数电缆 连接到MDF中心机房 第16页
智能化系统方案 设计中心三层及二层一各设置一个IDF,分别用于管理 层设计中心个楼层区域所有水平信息点,通过6芯多模光纤和100对大对数电缆连接到MDF中心机房 设备间均采用15U壁挂式标准机柜 放置主干网络设备和交换设备,用于统一管理从IDF到MDF之间的数据主干及ISP接入,并按照 客户的要求提供相应的网络服务,并提供ISP接入设备及接。 5、设计标准与依据 主要依据的国内标准及技术规范 《智能建筑设计标准》GB/T50314—2000; 《建筑与建筑群综合布线系统工程设计规范》GB/T 50311-2000; 《建筑与建筑群综合布线系统工程验收规范》GB/T 50312-2000; 《民用建筑电气设计规范》JGJ/T 16—92 《建筑设计防火设计规范》GBT 16-87 《大楼通信综合布线系统标准》YD/-1997 《中国电气装置安装工程施工及验收规范》(GBJ232—90—92) 《电气装置安装工程电缆线路施工及验收规范》(GB50168-92) 《通信光缆的一般要求》(GB/T7427—87) 《工业企业程控用户交换机工程设计规范》 主要依据的国际标准及技术规范 《用户建筑综合布线》ISO/IEC 11801第二版 《商业建筑线缆标准》EIA/TIA 568B; 《商用建筑通信通道和空间标准》EIA/TIA 569; 《商业建筑通信基础结构管理规范》EIA/TIA 606; 《商业建筑通信接地要求》EIA/TIA 607; 《非屏蔽双绞线布线系统传输性能测试标准》EIA/TIA TSB-95 IEC332-1阻燃要求 IEC61000-4-2静电放电条款 IEC61000-4-3电磁场条款 IEC61000-4-4高频干扰条款 IEC60068-2-2振动测试条款 IEC60068-2-27打击测试条款 产品选型 第17页
智能化系统方案 在本次设计中,我们推荐选用台湾综合布线专业制造商COMBO的结构化综合布线系统解决方案来实现办公楼的综合布线,设计充分考虑了计算机系统和网络的发展。COMBO综合布线系统是一组完整的布线系统,以双绞线和光纤为传输介质,以满足用户各种语音、数据、控制线路及影像传输之需求。此配线系统经介质转换,可支持世界上主要电脑设备,例如: IBM、DEC、WANG、HP、SUN、UNISYS、TANGAN、APPLOTFFU等,并可支持各种局域网络(LOCAL AREANETWORK)如ETHERNET、TOKEN RING、ARCNET PLUS 及APPLE TALK 和 FDDI 或 TPDDI等网路架构。 推荐COMBO公司产品 台湾COMBO公司是一家世界著名的布线系统公司,在设计、开发、制造以及部署电缆、结构布线系统和电缆管理解决方案的领域已有三十多年多的专业经验,在建立和规范工业标准方面的领先地位TM在业内无与伦比。COMBO的PREMISE CABLING SYSTEM布线解决方案不仅具有当今最好的端到端性能,足以应付未来的严峻挑战。 TM因此,我们推荐使用的台湾COMBO公司的PREMISE CABLING SYSTEM综合建筑物布线系统网络,正是能满足适应大厦计算机信息系统需求的最佳抉择。这是因为作为国际知名厂商所生产的布线系统产品,能满足当今计算机网络世界领域中的各种网路形态(例如Ethernet 10Base-T、Fast Ethernet 100Base-T、100VG-Anylan、IBM Token-Ring、Terminals to Hosts、FDDI、CuDDI/UTPDDI、ATM)以及用户程控交换机系统PBX的通讯需求,另外有关楼宇控制设备的弱电线路也可以走PREMISE TMTMCABLING SYSTEM产品线路,所以PREMISE CABLING SYSTEM综合布线产品将是集数据(Data)、语音(Voice)、视频(Video)及图象(Image)于一体的高集成度应用管理产品。 TMPREMISE CABLING SYSTEM是在全世界被广泛接受的一种布线技术。它能够使一次性的投资解决未来十五至二十年内的所有布线问题。 TMPREMISE CABLING SYSTEM是标准的端到端结构布线系统.该系统可根据用户的机构变化或技术要求随时进行调整,从而满足用户增长对可靠性,工作效率和传输数据量的要求. TMPREMISE CABLING SYSTEM适用于具有以下一个或全部特征的公司: 拥有众多的用户 多样化的网络设置 经常更新配置 多占点内部网络 异常繁重的网络通信 结构化布线是一项长期的基础设施投资,系统一旦建立,遍布已更新或替换,因而,一个性能良好,TM并能配合未来发展的系统十分重要,PREMISE CABLING SYSTEM产生质量远远超过业界标准,并且TM已与设计,安装和维护,在恶劣建筑环境中也能保持性能良好。 PREMISE CABLING SYSTEM质量 第18页
智能化系统方案 认证系统则为用户提供了长期可靠运作的保证。 TMPREMISE CABLING SYSTEM提供一系列综合布线产品以满足语音、数据、影象通讯要求。这些TM产品从简单的语音终端产品到5类高速100MHz 产品系统。PREMISE CABLING SYSTEM铜缆及光缆产品包括快接是配线架、跳线、信息出口、适配器、机柜、光纤跳线、光纤跳接设备、光纤切口工具及许多其他元件等。 多数企业的网络系统硬件每三,四年就更新一次。如果您的结构化布线系统不具备运行新设备的能力,TM网络投资将有可能浪费。PREMISE CABLING SYSTEM可以支持若干代网络的更新与发展并提供足够的发展空间,因而也可以保证您新设备或新技术的投资。要想获得生命力最长的系统,选择最先进技术是明智之举。 TMCOMBO PREMISE CABLING SYSTEM开放系统体系解决了众多从事通讯行业的人们所面临的TM难题:将多个厂家产品从LAN 到主机多路由集成起来。PREMISE CABLING SYSTEM开放系统体系着重提供可靠灵活的布线系统。该系统能确保现行高速网络数据信号的完整,同时支持新技术的应用。 TM开放系统体系包含6类非屏蔽双绞、屏蔽双绞及光纤技术。采用PREMISE CABLING SYSTEM布线系统能降低安装费用并减少设备变化时需做的重复布线工作,可以设计和安装可靠的端点到端点结构化布线系统,可支持任何厂家的话音、数据和图象设备。5类系统则可以支持100BaseTX、100Mbps、TPPMD,新技术如155Mbps的ATM及100BaseVGANYLAN。PREMISE CABLING SYSTEM开放系统体系可保障您的系统投资。 当今媒体的不断发展和技术的不断进步意味着在未来的10-15年里,网络上的信息传输量会极其庞大。信息交换讲究实时性,信息的采集、传播和分析将是现代企业以客户为本的运作机制的先决条件。 信息交换讲究时效性,信息收集、传播和分析将是现代以客户为本的组织机构运作的先决条件。 TMCOMBO公司的PREMISE CABLING SYSTEM能适应当今对网络应用的最高要求,并为未来的需求保留性能余量。PREMISE CABLING SYSTEM是有战略意义的IT资产,保证在网络信息的传输量增加时,用户的工作仍能流畅高效地进行。 TMPREMISE CABLING SYSTEM符合国际标准组织(ISO)和电子工业协会/电信工业协会(EIA/TIA)已定的、或制定中的国际标准。 TMPREMISE CABLING SYSTEM提供长达25年的质量保证,是端到端铜缆与/或光纤的完整解决方案。根据用户选定不同方案, COMBO的不同系列的产品都能提供最佳的网络性能。 通过提供端到端解决方案,COMBO确保用户在建立结构化布线系统时无需混使用不同供应商的产品和而使用COMBO统一的匹配产品。而且,我们的用户还获得了额外的保证:结构化布线系统中的所有部件已作为整体、一起经过了严格的性能测试,符合超五类或超五类系统的国际标准。 6、安装调试及测试 第19页
智能化系统方案 通信介质的正确连接及良好的传输性能,是关系到系统正常运转的基础。在该综合布线系统项目中我们将提供良好的物理链路和测试手段以满足业主不断深化和完善的营运需求,当综合布线系统全部安装完毕,我方将对所有链路进行100%的基本链路测试。当测试技术指标满足指标书要求后,将请客户认可的权威机构进行第三方测试。第三方测试采用抽样测试方法,抽样率为10%。测试不合格的线缆允许整改后再测试一次。 布线系统应满足ISO/IEC 11801-2000+ Class E的链路技术性能指标(表): Class E – 2000+, Permanent Link Freq. Insertion NEXT ACR NEXT ACR ELFEXT ELFEXT Return Return (MHz) loss pp pp ps ps pp ps Loss * Loss * 1 dB 4 dB 10 dB 16 dB 20 dB dB dB 100 dB 125 dB dB 175 dB 200 dB 250 dB All values are in dB * for insertion loss values > 4 dB 表链路技术性能指标 第20页
智能化系统方案 测试标准 光纤连接: 根据ISO IS 11801国际标准Optical Class之要求制定 Fluke被测线路的定义 双绞线链路连接: 测试跳线, 2米(最大) Permanent link, 90米(最大) 用户跳线 + = 10 米(最大) 设备端跳线 Channel Link, 100 米 (最大) 工作区跳线 第21页
智能化系统方案 (二)、设备安装与管线布放建议 1.工作区: 根据要求,全部选择墙壁安装型信息插座,提供标准的RJ-45 接口。可接电话、计算机、传真机等,并且根据国标规定,所有墙上型信息插座均距地300mm ;所有地面信息插座距强电插座中心距不小于300mm 。 为了美观,信息插座建议采用暗埋式插座 。为便于设备使用,每个信息插座附近应配备220V电源插座一组。 2.水平线缆走向建议: 根据建筑的实际情况,对于墙面信息出口,其水平线缆由楼层设备间的配线架引至本层吊顶的金属线槽内,在合适位置套穿金属软管经墙内暗埋线管沿墙敷设至信息出口。电源配套相应处理。 钢管接头盒 由吊顶内钢管接入 两根五类四对双绞线 300mm 地 面 3.垂直线缆布放建议: 垂直主干缆用电缆托盘或梯架固定。 4.配线架放置建议: 配线架均安装在各层配线间,在本方案中,配线架均为机柜安装型配线架,全部安装于标准的19英寸立式机柜中。 设备在MC内的布放位置附后 。 第22页
智能化系统方案 (三).系统所需的工艺条件 1.机房工艺需求 温度: 10C~27C °°湿度: 60%~90% 照度: 300 LUX 门宽:>900mm 面积: 100~200 平方米 承重: 5KN/ 平方米 使用防火门,至少能耐火1小时的防火墙和阻燃漆 2.设备管理间工艺需求 管理配线间应尽量保持室内无尘土、通风良好、室内照明不低于 150Lux。应符合有关消防规范、配置有关消防系统。每个电源插座的容量不小于 300W。 按照标准的设计要求,设备间尤其是要集中放设备的设备间,应尽量满足下面的要求: 将服务电梯安排在设备间附近,以便装运笨重的设备; 保持室内无尘或少尘 ,通风良好,亮度至少达30英尺/烛光; 安装合适的消防系统; 使用防火门,至少能耐火1小时的防火墙和阻燃漆; 提供合适的门锁,至少要有一扇窗口留作安全出口; 尽量远离存放危险物品的场所和电磁干扰源(如发射机和电动机); 设备间的地板负重能力至少应为500kg/平方米。 根据结构化布线系统的要求,在配线间安装布线硬件的墙壁上须覆盖涂有阻燃漆的3/4英寸(合)厚的木板。 PDS系统中典型的接线间,其可以走进人的最小安全尺寸是380×300cm,标准的天花板高度为240cm,门的大小至少为高宽1M,向外开。在主、分配线间,最好有供放置设备的设备柜,其大小可按设备的尺寸而定,一般采用木质或玻璃材料制成。在设备间尽量将设备柜放在靠近竖井的位置,在柜子上方应装有通风口用于设备通风。 第23页
智能化系统方案 3.系统使用电源要求 工作区:在每个工作区附近预留交流220V,5A电源插座一组(2个通用插孔,使用功率1000W),使用系数。 管理区:在每个配线间内预留交流220V,4×5A电源插座组一组(使用功率1600W)。 设备区:在主计算机机房内预留20KW三相配电总开关一个,三相及单相电源插座若干。 4.系统防火/防水要求 本系统防火/防水要求如下: ★所有电缆均为阻燃缆线。 敷线后使用防火材料有效封闭地板洞。 壁挂设备后附防火背板。 5.系统抗电磁干扰要求 本系统抗电磁干扰要求如下: 统一接地:在各配线间和中央控制室内预留接地端子; 接地电阻≤1Ω。 电磁屏蔽:所有线缆均封闭于镀锌金属线槽内。 保护:对于由楼外来的信号线选用防雷防高压的保护器,建议选用进口的110ANA1保护架(带4C保护器),或采用国内用于交换机上的过压过流保护器;在关键的网络设备的数据连线上串接防雷防浪涌电压的网络保护器,建议选用美国APC的PTEL4网络保护器(最大信息流100Mbps)。 第24页
智能化系统方案 施工方案及进度 为合理、及时地实施网络施工计划,公司将委派有经验的网络工程技术人现场考察:1天 员配合项目工程负责人员现场考察施工现场,并认真听取和吸收工程人员的意见,以便尽快制定出一份施工方案。 在现场考察的基础之上,双方工程技术人员取得共识做出具体施工方案,方案制定:1天 并报请双方领导同意;内容包括: (1)网络布线施工图; (2)各部门、岗位站点具体位置确认书; : 依据网络布线施工要求与规范,实施布线准备及施工。在施工过程中,做线路施工:30天 到安全、优效、高质量(已完成)。 为确保网络线路安全稳定运行,网线施工完毕后将及时进行测试。如有故线路检测:1 天 障,将及时排除。 各系统所使用设备:服务器、计算机、打印机和其它设备按照设计就位,系统安装:15 天 网线联通。对各系统所需数据进行初始化输入设置。软件开始试运行。 对所有上岗员工进行培训。 岗位培训:10 天 系统安装后,乙方配备技术人员24小时协助甲方工作,直至甲方系统使用软件运行:3天 人员能够独自完成软件的操作。时间大致10—15天,如有需要可适当延长,双方协商解决。 系统进入正常维护期。 后期维护 第25页
智能化系统方案 服务体系 对所有有意向的客户,均进行实地考察,在考察过售前服务 程中广泛征求客户的意见,写出客户对应用系统的实地考察 整体的需求报告 根据实地考察,形成实施方案,免费提交用户 制定方案 通过对施工对象的实际考察,向客户提供一份具体 工程施工方案,并按照方案进行施工:方案制定 线网络施工 路施工线路检测站点就位和网络调试等。 按照系统实施方案所规定的内容及步骤,对系统整现场服务 体,编码等进行初始化工作,并对系统软硬件各方 系统安装调试 面进行调试。 本公司对客户的所有操作人员及相关人员进行全 岗位培训 面培训。 系统投入运行时我公司将派专人在酒店实行现场 现场维护 维护, 帮助操作人员进一步熟悉和掌握新系统。结 合试运行情况, 可按酒店的要求, 对某些功能进行 适当的调整和修改, 使系统更趋完善。 凡在免费维护期内及与本公司签有维护与保软件升级 养合约的客户均享有软件优惠升级权利。 后期服务 本公司通过电话线路及调制解调器为客户提远程维护 供远程免费维护以解决临时发生的小问题 对于系统所发生的任何原因所造成的的问 迅速响应 题,本公司将迅速反应,派专人进行解决。 第26页
酒店 综合布线系统方案建议书 目 录 目 录 ·············································································································································· 1 定义与习惯用语 ······························································································································ 3 一. 综合布线系统概述 ·············································································································· 5 概述 ·································································································································· 5 结构化综合布线系统的必要性 ······················································································ 7 PDS结构化综合布线系统的组成 ··················································································· 8 二. 综合布线系统的特性 ········································································································ 12 兼容性 ···························································································································· 12 开放性 ···························································································································· 12 灵活性 ···························································································································· 13 可靠性 ···························································································································· 13 先进性 ···························································································································· 13 三. 建筑结构评估 ···················································································································· 14 确定设备间的位置 ········································································································ 14 干线系统的规模及其设计 ···························································································· 14 选择水平布线路由和方法 ···························································································· 15 四. 设计依据及方法 ················································································································ 15 设计依据 ························································································································ 15 设计目标的确定 ············································································································ 16 系统设计等级 ················································································································ 16 综合结构化布线支持的数据应用:············································································· 18 器件选择 ························································································································ 18 设计方法 ························································································································ 18 工作区系统 ···················································································································· 20 水平布线子系统 ············································································································ 20 垂直干线子系统 ············································································································ 20 设备间子系统 ················································································································ 20 五. 各子系统的设计 ················································································································ 20 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
工作区子系统 ················································································································ 20 水平布线子系统 ············································································································ 23 垂直干线子系统 ············································································································ 25 管理子系统 ···················································································································· 26 总投资估算 ···················································································································· 29 六. 综合布线系统测试手段方法和标准 ················································································ 30 测试原因 ························································································································ 30 测试模型 ························································································································ 30 双绞线系统的测试内容 ································································································ 31 光缆系统的测试 ············································································································ 37 七. 技术服务 ···························································································································· 37 布线系统管理文档 ········································································································ 37 完工测试 ························································································································ 38 竣工文档 ························································································································ 38 施工责任与质量保证 ···································································································· 39 八. 公司简介 ···························································································································· 39 九. 服务与质保 ························································································································ 40 十. 配套设计要求 ···················································································································· 40 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
定义与习惯用语 信息点 指布线系统中的一个设备连接点,与信息插座的一个插孔对应。较常见的信息设备是电话和计算机。 信息插座(Information Outlet) 布线系统中水平子系统的一部分,与工作区子系统相连。信息插座由面板和插孔模块等组成,面板分暗嵌式和外露式,插孔数也有多种。插座不与信息点一一对应,往往一个插座中既有计算机插孔又有电话插孔。 互补 电话和计算机插座的互补是指可以把计算机插孔改接电话,或把电话插孔改接计算机。互补对综合布线系统的设计有一定要求。 EIA/TIA Electronic Industries Association/Telecommunication Industries Association(电子工业协会/通讯工业协会)的缩写。EIA/TIA568是目前被业界广泛遵循的布线标准。 超五类 是EIA/TIA公告TSB-36和TSB-40中规定的支持150MBPS以下传输率的布线系统器件类别。如果要支持150MBPS的传输,要求这个布线系统的所有的器件,包括电缆和插接件,都必须是五类产品。 配线间(箱) 属布线系统的管理子系统,其中放置配线架。典型的,设备间(本设计中就是鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
主机房)中放置主配线箱;每层楼设一个卫星配线箱,卫星配线箱设置的多少随各楼层的信息点密度不同而不同。 配线架 配线间(管理子系统)中多种配线器件的总称。像配线间(箱)一样,也分为主配线架和卫星配线架;主配线架连接主干电缆和设备,卫星配线架连接水平电缆和主干电缆。 工作站 计算机网络中普通用户使用的计算机,与服务器相对,可以共享服务器上的资源。 配线架水平端 一般地,我们把配线架与水平电缆相连的部分称作水平端。 配线架垂直端 一般地,我们把配线架与垂直主干相连的部分称作垂直端。 阻燃电缆 指电缆点燃后在限定的时间内,火焰沿电缆蔓延到限定的距离内可以自动熄灭。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
一. 综合布线系统概述 概述 随着社会的发展,现代办公建筑往往需要敷设各种电缆,如电话线、数据线、电视线路、空调、灯光、火警、保安等;还有某些为满足特定需要而铺设的线路。每一条线路都是为一特定的用途而设计安装的。如果采用传统的方法,每一条线路的设计和安装都与其它线路不相干,而且各线路的线缆型号和规格也不相同,结果造成办公楼的管理者面对的是一些互不相关的线缆系统所组成的毫无组织的布线环境。 从历史上看,这种非结构化布线系统是由于分工和责任分担造成的。例如: 一个人负责话音(电话),而另一个人负责数据(计算机),各有各的需求和预算。线缆系统的供应商们同样也分为话音和数据两类,每一方都不知道也不关心另一方在做什么,再加上各式各样的楼宇控制及管理系统,情况就变得更加复杂。这就是过去大楼总是被线缆堵塞,而其中有大部分实际上已经废弃的原因。因此旧大楼要花大笔钱用于合并、转移、改动、重新安装电缆。 试想,如果在大楼或园区内有一个综合的布线系统,联接通讯、数据处理及传统的楼宇控制系统,那对使用者的益处是显而易见的,包括:减少人力物力的花费、一次性安装、系统集成只需一个连接点、需要的实际空间较小、降低重新布置(移动或改变)及维护管理的费用,而且能够更轻松地采用新的技术,降低风险和费用。 结构化综合布线系统(Premises Distribution System--PDS)就是这样一个系统。 建筑物综合布线系统(Building Premises Distribution System)又称开放式布线系统(Open Cabling System)是一种在建筑物和建筑群中综合数据的网络系统。它是把建筑物内部的语音交换、智能数据处理设备及其它广义的数据通信设施相互连接起来,并采用必要的设备同建筑物外部数据网络或电信局线路相连接,其系统包括所有建筑与建筑群内部用以交连以上设备的电缆和相关的布线器件。 综合布线系统是1985年内美国电报电话公司公司贝尔实验室首先推出,并于1986年通过美国电子工业协会(EIA)和通信工业协会(TIA)的认证。于是很快得到世界广泛认同,并在全球范围内推广。PDS出现的意义,在于它彻底打破了数据传输和语音传输的界限,并使这两种不同的信号在一条线路中传输,从而为综合业鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
务数据网络(ISDN)的实施提供了传输保证。 建筑物或建筑群内办公自动化设备都是因用户的应用需要而设置的。在传统上,具体应用都以各自满足不同应用的需求而设计、安装,其结果就是难以对整幢大楼的所有线路进行有效的管理;更有甚者,对将来网络改造造成很大的困难。如果有一个结构化综合布线系统可以把整个大楼的所有线路集成在一个布线系统中,统一设计、统一安装,这样不但减少了安装空间、改动费用、维修和管理费用,而且能较轻易地以较便宜的成本及可靠的技术接驳最新型的系统。 结构化综合布线系统是建筑物内的信息传输网络。结构化综合布线系统由不同系列的部件组成,其中包括:传输介质,线路管理硬件、连接器、插座、插头、适配器和支持硬件。上述这些部件被用来构建各种子系统,它们都有各自的具体功能与作用。不仅易于实施,而且能随需求的改变而平稳过渡增强型分布技术。 结构化综合布线系统的设计,要求系统设计师在对拟议的布线系统解决完之前,安全而彻底地评估用户的需求。以便该结构化布线系统的设计更加合理、可靠。 大家都知道,要实现智能化办公大楼,计算机网络和结构化综合布线系统是智能化大厦基础设施的重要组成部分,而结构化综合布线系统在上述基础设施中的重要性方面较计算机网络更为重要。 PDS是一套综合的布线系统。PDS是针对计算机与通信的配线系统而设计的,这也就表明它可以满足各种不同的计算机与通信的要求。包括: 1) 模拟与数字的语音系统 2) 高速与低速的数据系统 3) 传真机、图形终端、绘图仪等需要传输的图像资料 4) 电话会议与安全监控系统的视频信号 5) 传输28个VHF宽带视频信号 6) 建筑物的安全报警和空调控制系统的传感器信号 PDS可满足建筑物内部及建筑物之间的所有计算机、通信以及建筑物自动化系统设备的配线要求。由于PDS是一套综合式的系统,因此它可以使用相同的电缆与配线端子板,以及相同的插头与模块化插孔以供语音与数据的传递,可不考虑各种设备的兼容性问题。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
结构化综合布线系统的必要性 现代通信发展的需要 通讯技术是现代经济发展的媒介,而智能型大厦(楼)技术的核心正是通信技术。现代通信工业的发展具有这样几种趋势:计算机和通信工业朝世界性的标准化和通信设施的个人化方向发展;计算机和通信工业朝系统集成的方向发展。综合业务数字网(ISDN)的发展,表明要把尽可能多的通信、计算机功能集成到一个单一的系统中;要把所有的业务,包括话音、数据和图像都转换成数字的形式进行统一处理;光纤技术引入局部通讯网(包括局部用户回路和办公室大厦等),如光纤数据分布接口(FDDI)。 智能型办公大楼的核心是通信技术。 智能大厦系统正是为了适应现代通信技术的发展而产生的。现代通信技术的发展非常迅速,这就要求我们以强有力的通讯系统作为大厦智能化的核心,并利用大厦配线系统提供的灵活性、模块性、开放性,来满足用户目前和将来的需要。 智能型办公大楼运转费用及经济效益的需要 在传统大厦设计的相当早期阶段,就应该有房地产开发商、用户和通信设计人员共同参加,并要提前一段时间先设计方案,选择设备供应商,还要给设备供应商一段时间,才能完成设备的选购;同时要想在短时间内,解决因各种技术方案和用户需求在客观上必然会有的不确定性和易于变化所带来的复杂问题,是非常困难的。 然而,PDS布线系统可以提供一个工程性能良好的平台。利用这个平台可以提供任何类型的大厦业务,使这个建筑项目有很大的灵活性和通用性,同时, 又是以非常迅速和好的性能价格比的方式实现。 方便用户使用 智能大厦(楼)系统可以给建筑者和管理者提供一种功能, 使得当工作人员因位置变动、业务变更(增加、移动等)时候,需要支付的大规模修建费用保持在最低。末端用户的业务请求,如电话、微机等设备的重要布局或增加额外的办公室功能等,都易于在建筑期间或大楼的生命周期内完成,不必重新设计网络或使用附加配线,就能保证对用户的需求做出最快的反应。而在传统大厦里,这类反应通常需要几个星期。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
随着技术的发展,所需的集成费用降低 PDS布线系统可以把所有不同类型的电话系统(包括ISDN)和由有关单位提供的能源、保安、火灾安全等系统都集成在一起。因此随着技术发展所需的集成问题以及与此相关的费用都可以保持在尽可能低的程度。 PDS结构化综合布线系统的组成 PDS采用模块化设计,因而最易于配线上扩充和重新组合,此系统采用星形拓扑结构,并同电信方面以及EIA/TIA568所遵循的建筑物配线方式相同。 由于它采用了星形拓扑结构的模块化设计,才使扩充系统工作变得十分方便。因为在星形拓扑结构中,工作站是由中心节点向外增设,而每条线路都与其它线路无关,因此,在更改和重新布置设备时,只是影响到与此相关的那条线路,而对其它所有线路毫无影响。另外,这种结构会使系统中的故障分离工作变得非常容易。一旦系统发生故障,便可迅速地找到故障点,并加以排除。 PDS布线系统包括布置在楼群中的所有线缆以及各种配件,如转接设备、各类用户端口以及与外界网络的接口(如电话局)等(但不包括各种交换设备)。PDS布线系统的地位如下图所示: 计算机设备 外部通信环境 网络接口 通信设备 综合布线系统 通信管理系统 综合结构化布线系统是智能大厦必不可少的部分,它由六个子系统组成,采用星形结构,并使任何一个子系统独立地进入PDS系统中。它们是: 工作区子系统(WORK AREA): 工作区子系统由终端设备连接到信息插座的连线组成,它包括连接器和适配器。由终端设备和连接到信息插座的连线组成,包括信息插座、插座盒(或面板)、装配软线,适配器和连接所需的扩展软线,并在终端设备和I/O之间搭桥。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
工作区子系统中所使用的连接器必须具备有国际ISDN标准的8位接口,这种接口能接受大厦自动化系统所有低压信号以及高速数据网络信息和数码音频信号。 水平布线子系统(HORIZONTAL CABLING): 实现信息插座和管理子系统(跳线架)间的连接,常用PC101004或PC101004连接。从用户工作区连接至垂直主干线子系统的线路便是水平布线子系统。水平布线子系统总是在一个楼层上,并与信息插座连接。在综合布线系统中,水平子系统由4对UTP组成,能支持大多数现代通信设备。如果需要某些宽带应用时,可以采用光缆。 水平布线子系统的功能是将干线子系统线路延伸到用户工作区。如前所述,水平系统是布置在同一楼层上的,一端在信息插座上,另一端接在层配线间的配线架上。在有些要求宽带传输时,可采用“光纤到桌面”的方案。当水平区间面积相当大时,在这个区间内可能有一个或多个卫星接线间,水平线除了要端接到设备间之外,还要通过卫星接线间,把终端接到信息出口处。 主干线子系统(BACKBONE CABLING): 干线子系统又称垂直主干线子系统,它提供建筑物干线电缆的路由。实现计算机设备,程控交换机(PBX),控制中心与各管理子系统间的连接 ,常用介质是大对数双绞线电缆、光缆。干线子系统通常在2个单元之间,特别是位于中央点的公共系统设备处提供多个线路设施。该子系统由所有的布线电缆组成,干线子系统业务中继交叉连接点和网络接口连接起来,网络接口通常放在设备相邻近的房间。网络接口为这些设施和建筑物综合布线系统之间划定界限。 干线子系统是由主设备间(如计算机房,程控交换机房)至各层管理间。采用大对数的电缆或光纤,两端分别端接到设备间和管理间的配线架上。 管理子系统(TELECOMMUNICATIONS CLOSET): 管理子系统由交连、互连配线架组成。管理点为连接其它子系统提供连接手段。交连和互连允许将通讯线路定位或重定位到建筑物的不同部分,以便能更容易地管理通信线路。使在移动终端设备时能方便地进行插拔。它是干线子系统和水平子系统的桥梁,同时又可为同层组网提供条件。其中包括双绞线、配线架、跳线。在有光纤需要的布系统中,还应有光纤配线架和光纤跳线。当终端设备位置或局域网的结构变化时,有时只要改变跳线方式即可解决,而不需重新布线。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
管理子系统由交连、互连以及I/O组成。管理点为连接其它子系统提供连接的手段。交连和互连允许将通信线路定位或者定位在建筑物的不同部分。以便能更容易地管理通信线路。I/O位于用户工作区,使在移动终端设备时能方便地进行插拨。 根据布线安排和管理通信线路以适应终端设备位置变化的需要,在各种不同的交叉连接处可选用插入线。但在中继线交叉连接处。布线交叉连接处和干线接线间里,通常已安装好使用插入线的交叉连接硬件。 设备室子系统(EQUIPMENT ROMM): 设备子系统由设备间中的电缆、连接器和相关支撑硬件组成,它把公共系统设备的各种不同设备互连起来。该子系统将中继线交叉连接处和布线交叉处与公共系统设备(如PBX )连接起来。 它是由设备间中的电缆,连接配线架及相关支撑硬件,防雷电保护装置等构成。比较理想的设置是把计算机房、交换机房等设备间设在同一层中,这样便于管理,又节省投资。当然也可根据建筑物的具体情况设计多个设备间。它的作用是把公共系统设备的各种不同设备连接起来。该子系统将中继线交叉连接处和布线交叉连接处与公共系统设备连接起来。该子系统还包括设备间和邻近单元如建筑物的入口区中的导线。 建筑群(ENTRANCE FACILITIES)子系统: 建筑群子系统将一个建筑物中电缆延伸到建筑物群的另外一些建筑物中的通信设备和装置上。它支持提供楼群之间通信所需的硬件。实现建筑物之间的相互连接,常用通信介质是光缆,主干线和建筑群间使用光缆。 需要指出的是,对数据通讯而言,主干线和建筑群间使用光缆,并使用FDDI 或ATM技术,可使系统间的传输率达100Mbps或155Mbps。对工作区而言,如果使用Cat 5 UTP电缆,则目前技术可达100Mbps (100Base-T);而对超五类 UTP电缆,对目前设备而言,可达155Mbps。 当今社会,“智能大厦”的概念正在被越来越多的人们所接受,当人们投入巨资去建设现代化办公大楼、厂房、飞机场时,毫不犹豫地配备了电话、传真、计算机、安全监控、电视、空调等一系列设施。而综合结合化布线系统恰恰是整个信息技术网络的生命线,是所有商务办公活动所依赖的基础,一个被很好地设计、安装和管理的综合结构化布线系统将大大减少建筑物各个生命阶段的消耗。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
结构化综合布线系统示意图 水平布线子楼层配线 单用 管理子系 工作区子系 用户 楼层配线水平布线子 垂直主干子单用管理子系 工作区子系 用户 主配线水平布线子 单用管理子系 工作区子系 用户 设备子系 建筑区子系 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
二. 综合布线系统的特性 综合布线系统是一个全新的概念,它同传统的布线相比较,有着许多的优越性,是传统系统所无法企及的,其特性主要表现为它的兼容性、开放性、灵活性、可靠性、先进性和经济性。另外在设计和施工方面也给人们带来了许多方便。 兼容性 综合布线系统的首要特性是它的兼容性,所谓兼容性是指其它设备或程序可以用于多种系统中的性能。 过去,为一幢大楼或一个建筑群内的话音和数据线路布线时,往往采用不同厂家生产的电缆线、配线插座以及接头等。例如用户交换机通常采用双绞线,计算机系统通常采用粗同轴电缆或细同轴电缆。这些不同的设备使用不同的配线材料构成网络,而连接这些不同的配线接头、插座及端子数也各不相同,彼此互不相容。一旦需要改变终端机或电话机位置时,就必须改敷新的线缆,以及安装新的插座和接头。 综合布线系统数语音信号、数据信号与监控设备的图像信号配线经过统一的规划和设计,采用相同的传输介质、信息插座、交连设备、连配器等,把这些性质不同信号综合到一套标准的布线系统中。由此可见,这个系统比传统布线系统大为简化,这样可节约大量的物质、时间和空间。 在使用时,用户可不用定义多个工作区的信息插座的具体应用,只把某种终端设备(个人计算机、电话、视频设备等)接入这个信息插座,以后在管理间和设备间的交连设备上做相应的跳线操作,这个终端设备就被接入到自己的系统中。 开放性 对于系统的布线方式,只要用户选定了某种设备,也就选定了与之相适应的布线方式的传输介质,如果更换另一种设备,那原来的布线系统就要全部更换。可以想象,对于一个已经完工的建筑物,这种变化是十分困难的,要增加很多新的投资。 综合布线系统由于采用开放式体系结构,符合多种国际上流行的标准,因此它几乎对所有著名厂商的产品都是开放的,如IBM,HP、DEC、SUN的计算机设备,并对几乎所有的通信协议也是开放的,如EIA-232-D,RS-422,RS-423,Ethernet, Token-Ring, FDDI, ISDN, ATM等。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
灵活性 传统的布线方式由于各个系统是封闭的,其体系结构是固定的,若要迁移设备或增加设备是相当困难而麻烦的,甚至是不可能的。 而综合布线系统,由于所有信息系统皆采用相同的传输介质,物理星形拓扑结构,因此所有信息通道都是通用的。每条信息通道可支持电话、传真、多用户终端。所有设备的开通及更改均不需改变系统布线,只需增加相应的网络设备以及进行必要的跳线管理即可。另外,系统组网也相当灵活多样,甚至在同一房间可有多用户终端、10Base-T工作站、令牌环工作站并存,为用户组织信息流提供了必要的条件。 可靠性 由于传统的布线方式各个系统互不兼容,因而在一个建筑物中,往往要多种布线方式,因此,建筑系统的可靠性要由所选用的各个系统的可靠性来保证,而且如果各系统布线不当,还会造成交叉干扰。 综合布线系统采用高品质的材料和组合压接的方式构成一套高标准信息通道。所有器件均通过UL,CSA及ISO认证,每条信息通道都要采用专用仪器校核线路阻抗及衰减率,以保证其电气性能。系统布线全部采用物理星形拓扑结构,点到点的端接,任何一条线路故障均不影响其它线路的进行,同时为线路的运行维护及故障检修提供了极大的方便,从而保证了系统的可靠运行。各系统采用相同的传输介质,因而可互为备用,提高了备用冗余。 先进性 当今社会信息产业飞速发展,特别是多媒体使信息和话音传输界限已被打破,因此现在建筑物若采用传统布线方式,肯定是落后的。它不再能满足目前信息技术的需要,更不能适应未来信息技术的发展。 综合布线系统应用极富弹性,采用光纤双绞线混布方式,极为合理地构成一套完整的布线系统。所有布线均采用世界上最新通信标准,信息通道均按B-ISDN设计标准,按8芯双绞线配置,通过超5类双绞线,数据最大速率可达到155mbps,对于特殊用户需求可做到光纤到桌面。干线光纤为将来的发展提供了足够的余量。通过主干通道可同时传输多路实时多媒体信息,同时物理星形的布线方式为将来发展高速交换式网络奠定了坚实的基础。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
三. 建筑结构评估 风采酒店大楼结构化布线是一个具有184个数据点的布线系统工程。所有的、数据点都在风采酒店大楼内第八层。 建筑物综合结构在布线的直接对象是建筑物或建筑群,在进行建筑PDS系统设计时,必须首先对其结构做出评价,提出自己的建议。建筑物综合布线系统设计需完成以下几个方面的设计,即: (1)确定设备的位置及大小 (2)设计干线子系统 (3)设计远程通信接线间,即卫星接线间 (4)选择一种布线方法,从而进一步确定工作区主线从干线接线间和远程通信接线间到I/O设备的路由。 确定设备间的位置 设备间是一个安放很多用户共用设备的空间,其中包括主布线区和LAN之间的交换装置及相关的支撑硬件组成,是网络接口,计算机数据传输电缆和用户建筑物布线系统交汇点。 风采酒店主设备间设在一层的风采酒店大楼中心监控室,另设一个分设备间在酒店的十层弱电房。 干线系统的规模及其设计 干线系统是整个风采酒店大楼及管理通信的骨架,干线系统把主设备间的电缆引向不同的楼层,并进行单点、双点管理,为各楼层提供所需的数据通信。干线系统由以下几部分组成: ·管理设备 ·数据通信电缆 ·电缆井 干线系统设计的优劣将直接影响到未来通信的效率,它不仅用来容纳数据线缆,而且也用来端接某一给定楼层上的一些I/O设备,是布线系统的中枢神经。 本方案基于方便设计,电缆井设在酒店的弱电井内。为了便于维护及考虑系统的维护性和可扩展性,本方案书提出数据通讯及语音全部集中到大楼的中心监控室和分配线间。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
选择水平布线路由和方法 选择一种介质布线方法来将工作区线缆由干线连接间到I/O,这样做的目的是为了设计出最短的电缆布线,因为这会降低布线的费用,同时也是为了设计较易于安装的路由。 电缆路由受到很多种因素的影响,其中包括: ·建筑物的功能 ·关系考虑 ·电磁干扰 ·特定路径的优缺点 由于风采酒店的结构化布线为新建工程,考虑到建筑物功能等多种因素,故布线工程的所有的布线走内墙或走地槽,墙内和垂直管道选用优质的PVC管,地槽采用专用的线缆槽。 四. 设计依据及方法 设计依据 标准 · 10Base-T、100Base-TX、100Base-FX ·EIA/TIA 568,EIA/TIA 569,EIA/TIA-TSB 36/40 ·ISO/IEC JTC1/SCIS/SG3 ·ANSI FDDI/TPDDI 安装与设计规范 ·中国建筑电气设计规范 ·Open Cabling Systems PDS结构化布线系统设计总则 ·建筑与建筑群综合布线系统工程设计规范(CECS 72:95) ·建筑与建筑群综合布线系统工程设计规范(CECS 72:95)条文说明 ·工业企业通信设计规范 ·城市住宅区和办公楼电话通信设施设计标准 ·市内电信网光纤数字传输系统工程设计暂行技术规定 ·市内电话线路工程设计规范 ·市内通信全塑电缆线路工程设计规范 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
·通信局(站)接地设计暂行技术规定 设计目标的确定 设计目标的确定 根据风采酒店的具体要求,我们对计算机数据传输线路进行设计。 设计范围: ·计算机数据传输线路。 设计原则 我们的设计采用Open Cabling Systems的思想进行,使整个网络系统具有实用性、灵活性、可扩充性,以及真正的开放性。一次性布线,保证在15年内其系统性能不会下降,功能不会落后,不会因为网络配置的变化而如旧布线方法那样重复土木工程。破坏建筑物原有的结构,增加不必要的投资,真正地达到一次性投资,长年受益。 ·实用性 能支持各种数据通信、多媒体技术以及信息管理系统等,并且能适应现代和未来技术的发展。 ·灵活性 任意信息点能够连结不同类型的设备。如微机、打印机、终端、服务器等。 ·开放性 能够支持任何厂家的任意网络产品,支持任意网络结构(总线、星型、环型等)。 ·模块化 除去敷设建筑内的水平线缆外其余所有的插件都应是积木化的,以方便使用、管理和扩充。 ·扩充性 实施后结构化布线系统是可扩充的,以便将来有更大的需求时, 很容易将设备安装进去。 ·经济性 一次性投资,维护费用极低,使整体投资达到最小。 系统设计等级 结构化综合布线系统设计等级应根据不同的具体要求,给出不同的设计等级。结构化综合布线系统设计等级可分为三个等级: 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
基本型设计等级 1)每个工作区至少有一个信息插座 2)每个工作区至少有一个水平布线(4对UTP)系统 3)全部采用110A交叉连接硬件----与未来增加的设备兼容 4)每个工作区的干线电缆至少有两对双绞线 基本型设计等级支持数据产品,并能升级到数据或综合型布线等。 基本型设计等级具有如下特征: 1)能支持所有语音和某些数据处理应用 2)语音、综合型语音/数据式高速数据应用 3)方便技术人员管理 4)支持所有AT&T、IBM等设备的信号传输。 增强型设计等级 增强型设计等级支持语音和数据处理的应用,并且可按需要和应用对接线板进行管理。这种类型的设计方案不仅具有增强功能,而且还可以提供发展的余地。 增强型设计等级对配置有如下要求: 1)每个工作区有两个以上的信息插座 2)每个信息插座有独立的水平布线(4对UTP)系统 3)110A或110P交叉连接硬件 4)每个工作区的干线电缆至少有三对双绞线 增强型设计等级有如下特征: 1)每个工作区有两个以上信息插座 2)任何一个信息插座都可提供高速数据处理应用 3)客户可以利用接线板进行管理 综合型设计等级 综合型设计等级的特征是把双绞线和光纤纳入建筑物综合布线系统。 这种设计等级需要的配置为: 1)每个工作区的建筑群电缆内配有2对双绞线 2)每个工作区的干线电缆中有3对双绞线 3)在建筑群、干线或水平布线子系统配置微米光纤 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
综合设计等级的特征: 1)每个工作区有两个以上信息插座 2)任何一个信息插座都可以提供语音和高速数据处理应用 3)客户可以利用接线板进行管理 4)光纤的管理可以利用光纤连接器 根据风采酒店的具体情况,以及考虑到今后的发展,我们建议采用增强型设计等级进行设计。 综合结构化布线支持的数据应用: 我们的设计所支持的数据应用如下: ·AT&T PBX(Merlin、System 25,75,85和SESS)/终端设备(模拟、数字和混合型) ·PBX ·3270数据模块可支持IBM3270型设备 ·数字化多路复用接口(MDI) ·综合业务数据网(ISDN),基本速率接口(BRI),主要速率接口(PRI) ·AT&T ISN StarLAN ·非屏蔽双绞线上的Synoptic 100Mbps 以太网方案(介质支持) ·ATM方案、Fast Ethernet、FDDI、Token-Ring(介质支持) ·其它 器件选择 信息插座: ·RJ45超五类插座支持数据 水平线缆: ·超五类双绞线支持数据,支持多媒体数据的传输 主干线缆: ·4芯多模光纤支持主干和5类25对UTP 配线架: ·光纤配线架或超五类Patch Panel支持数据, 设计方法 综合布线系统应能满足所支持的数据系统的传输速率要求,并应选用相应等级的线缆和传输设备,我们采用综合型设计等级,并采用开放式设计方法对此工程进行设计,以能满足所支持的数据系统的传输标准要求。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
塘酒店综合布线示意图 对十二楼 数据点??用?条水平双绞 语音点?? 户 ?分配线间? 数据点提㌲条水平双绞十一楼 语音点 出 十楼 交 的 数据点(分机房) ㌲条水平双绞 语音点各 配线架 五到十二楼为客房,每层均为23数据点, 个(共计190数据点)分配线间设在八楼 系 大对数据点㌹水平双绞线 九楼 统 语音点 分数据点㐱条水平双绞电缆 光纤 八楼 语音点别 进垂直竖井 数据点ㄵ条水平双绞行七楼 语音点 详数据点 ㄶ条水平双绞 细六楼 语音点 交 设数据点 㐵条水平双绞 五楼 ?主配 线计: 语音点 ?主机房? 共计信息点3088个(语音点162个,数据点 考虑 风采酒店实际情况,根据上述原则,我们对凯悦酒店大楼按如下4个子系统进行设计: 1、工作区子系统 2、水平布线子系统 3、垂直干线子系统 4、设备间子系统 去浮酒店的网络拓扑图如下: 设计说明 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
1、设计包括大楼内每层的计算机系统通信用的水平布线 。 2、设计包括大楼内计算机系统垂直布线。 3、TCL Open Cabling System六个子系统的设计思想和用户需求,将本设计方案划为四个子系统,即: 工作区系统 为用户提供一个ISDN标准的RJ-45通用信息出孔,连接水平子系统及各工作区的端接口设备,本根据需求,分别采用单孔和双孔信息插座。 水平布线子系统 用于将工作区子系统引至管理子系统,本方案建议书所述需求分析未得到用户认可,只作为参考。 由于将工作区子系统引至管理子系统,本方案采用Cat5E 8芯UTP,CAT5 E UTP支持数据传输155Mbps/60m、150Mbps/90m、10Mbps/150m。 垂直干线子系统 建议在大楼每层在靠近竖井处均设置配线架,用于管理各楼层水平子系统。其配线架视不同需求建议采用Cat5E Patch Panel或光纤汇接箱。本方案不涉及该系统的设计。 设备间子系统 作为大楼的主控中心,应用户要求设在中心监控室。 五. 各子系统的设计 工作区子系统 工作区子系统是指从终端设备到信息插座的整个区域,即一个独立的需要设置终端的区域划分为一个工作区。本工作区支持计算机数据通信。 根据已掌握的用户需求,确定信息插座的类别为超5类(Cat5E UTP RJ-45)。从而为用户提供一个ISDN标准的RJ-45通用信息出孔,连接水平子系统及各工作区端接的设备,分别采用单孔和双孔插座,这样做的好处是便于管理。每层数据点的个数根据用户需求而定。 工作区布线子系统由终端设备连接到信息插座的连线组成。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
工作区子系统示意图 工作区子系统信息插座安装位置确定: 对于办公楼环境而言,办公空间有大开间,也有四壁的小房间。对这两种形式下的工作区子系统的设计采用两种不同的方法。 小房间不需要分隔板,信息插座只需安装于墙上;通常按每10平方米1个双孔。 对于大开间而言,要使用分隔板将大开间分成若干个小工作区,对信 息插座的选用、安装方法、安装位置就受分隔板使用的影响,因为分隔 板可能会时常移动。因此,建议在本项目中,在大开间设立 配线管理区,以满足用户对网络系统应用的灵活性和可扩展性。 对于分隔板的使用,信息插座安装可有三种形式。下面简要说明这三种 形式的安装方法: 1)信息插座安装于地面上。要求安装于地面的金属底盒应当是密封的、防水、防尘并可带有升降的功能。此方法对于设计安装造价较高。并且由于事先无法预知工作人员的办公位置,也不知分隔板的确切位置,因此灵活性不是很好。 2)信息插座安装于分隔板上。此方法适于分隔板位置确定以后,安装造价较为便宜。 3)信息插座安装于墙上。此方法在分隔板位置未确定情况下,可沿大开间四周的墙面每隔一定距离均匀地安装RJ45埋入式插座。此方法比前两种方式,无论在造价、移动分隔板的方便性、整洁度、安装和维护造价上都是很好的。 4)信息插座安装在吊顶上。此方法用于楼宇自控系统、监控系统、门禁系统等, 采用BIX DVO系列模块盒,放置在吊顶棚上,与探头、摄像头、控制器通过跳 线相连接。RJ45埋入式信息插座与其旁边电源插座应保持20cm的距离,信息插座和电 源插座的低边沿线距地板水平面30cm。如下图所示: 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
G20 PVC管 信息插座 电源插座 20 cm 30 cm 地面 工作区信息出口(IO)数量的确定及选型: . 凯悦酒店信息点数量的确定: 由于系统应用的范围广泛,包含的系统多,因此需要保证足够的信息点数。否则,在将来系统使用中再进行扩充的话,将会付出非常大的代价。国外对此的统计是:系统扩充的平均花费将达US$6,000/IO(信息出口)。该统计不仅包括了扩充系统所需的材料费及运输费、人工费;还包括扩容时所引起的对建筑物的外观及内部结构的破坏、系统暂停使用和施工干扰给大楼的使用者带来的商务上和经济上的损失等,由于出现预留的信息点不能满足需要的情况,客户要求重新增加信息点,这不仅增加了施工的难度,也给客户带来了不必要的开支。重新加点的造价,比设计时就已经纳入的情况要高出3倍。所以,在系统设计时就应该保证必要的信息点数量。本项目中,具体点数已由贵方定好,我们将遵照执行。 . 风采酒店信息点产品型号的选型: 工作区由终端设备连接到信息插座的连线和信息插座所组成,通过插座既可以连接数据终端及其它传感器和弱电设备。在RJ45插座内不仅可以插入数据通讯通用的RJ45接头,也可以插入电话机专用的RJ12插头。信息出口(IO)采用的是单孔模块插座 ,单孔IO采用拆装灵活的、外观平整、洁白的模块式8PIN信息插座。该插座具有性能高、尺寸小、安装简便等特点,其输入、输出线的线规都符合EIA/TIA568标准。 . 信息点统计 本子系统经过统计,I/O节点共计308个(分布见表1)。 表1 信息点分布表 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
序号 楼层 语音点(V) 数据点(D) 模块(V/D) 面板 1 1楼 30 23 53 34 2 2楼 1 0 1 13 3 3楼 4 1 5 4 4 4楼 3 1 4 3 5 5楼 6 3 9 6 6 6-11楼 96 96 192 192 7 12楼 15 15 30 30 8 13楼 7 7 14 14 合 计 162 146 308 296 水平布线子系统 水平布线子系统是将干线子系统线路延伸到用户工作区。该系统是从各个子配线间出发连向各个工作区的信息插座。水平子系统将各工作区引至管理子系统,本方案采用Cat5E UTP非屏蔽八芯双绞线,其传输速率高,满足高速率传输要求(ATM,FDDI等)。在设计中充分考虑到房间将来的使用变化和满足数据通信的需要,为此,我们建议选用TCL国际电工(惠州)有限公司优质非屏蔽双绞线,支持多种类型的数据传输。 由于该大楼内的信息点均为固定的信息点,因此,水平布线由就近设备间的配线架引出。所有的水平布线,通过地板暗敷的PVC管引至各工作区。 水平布线可采用各种方式,要求根据建筑物的结构特点与其它工作的配合,用户的不同需求进行灵活掌握。对于大开间办公区可采用内部走线法或在混凝土层下敷设金属线槽,采用地面出线方式(如下图)。 水平区的设计 水平线拉至大开 水平子系统示意图 间的小配线架或插座架即可 水平线缆路由设计: 走廊的吊顶上应安装有金属线槽,进入房间时,从线槽引出PVC管以埋入方式由墙壁而下或通过地板槽到各个信息点。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
地板下走管布线法示意图 水平线槽?内穿水平线或光吊顶 预埋P噃管 办公间信息插座(包括面板、 模块和铁盒)每个插由计算机引出的孔功能可任意 削㐵接头 数据系统线路的水平部分,采用TCL超五类的水平线PC101004(TCL)。系统有非常好的灵活性,而且对未来数字电话,可视电话和速度高于100Mbps的多媒体高速数据应用均有很好的支持。 568标准的第五类线。它在传输数据时,可以在150米范围内标准10Mbps的传输速率,在100米范围内保证155Mbps的传输速率。此外它也可以传输各种70V直流电压及在相应的距离下传输10MHZ及100MHZ频率以内的弱电信号。 水平区数据计算如下。 在风采酒店大楼主设备间的水平布线部分,采用高架地板布线方法。高架地板也叫活动地板,任何一个方块都是可活动的,可方便接触到下面的电缆。这种布线方法非常灵活,而且容易安装,不仅容量大,而且防火也方便。缺点是初期鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
安装费用较高。 线缆计算如下: C=【信息点】×60米 总计18480米,折合超五类双绞线62箱。 表2 水平子系统材料估算表 序号 CAT 5E UTP(箱) 1 62 合计 62 垂直干线子系统 垂直主系统主要用于连接各个区域的分配线室,并连接主配线室。 垂直干缆路由设计: 主干应安放在金属线槽中,且每隔数米用一根扎带固定,以安装和固定垂直子系统的电缆。如一楼及二楼之间有竖井,竖井中的线槽应和各层配线室之间有金属线槽连通。 插座架 插座架竖井 插座架大对数电缆或光纤HOST主机房 干线区子系统示意图 垂直干线的选型与计算: 实现计算机设备,程控交换机(PBX),控制中心与各管理子系统间的连接,常用介质是大对数双绞线电缆、光缆。垂直干线部分提供了建筑物中 主配线架与分鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
配线架连接的路由,常采用BDNPLUS型、ATMM或DFlex型 大对数铜缆和 垂直干线的材料统计: 表3 垂直干线子系统材料估算表 序号 名称 数量(米) 1 光纤 50 2 50对数电缆 100 合计 管理子系统 该系统即可以是设备间子系统也可以是管理子系统。根据用户需求,管理系统是在五层的机房,在设备间中,主要包括配线架及交换机,构成系统的管理中心和通信枢纽。此设备间子系统交连方式取决于工作区设备的需要和数据网络的结构。 单点管理和双点管理 在不同类型的建筑物中,此设备间子系统可供选择的有两种方式,即单点管理双绞连和双点管理双绞连。 单点管理双交连: 一般当建筑物的规模不是很大,管理规模适中时,宜采用单点管理双交连方式。单点位于设备间的交换机或计算机主机附近,通过干线连接至管理配线间的第二个交连区。如果没有配线间的第二个交连点,可设置在用户间的墙壁上。 双点管理双交连: 当建筑物单层面积较大,管理规模大时,多采用二级交接间,即采用双点管鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
理双交连方式。双交管理除了在设备间有一个管理点外,在管理配电间(主配线间)仍有一级管理交连(跳线),如下图: 在每个交连区实现线路管理是采用各种色标之间跳线的方法实现的,这些色标用分别标识各场是哪一种类型的线缆,如干线电缆,水平电缆或设备电缆。 本方案设计采用单点管理双交连方式,水平配线管理采用Patch Panel,垂直主干配线管理设备由主干线路布线所不同而不同,分别采用TCL光纤汇接盒和TCL Cat 5e Patch Panel。 主(分)配线间的设计 配线间的管理子系统由用于交连、互连的插座架组成。为连接其它子系统提供连接手段。交连和互连允许将通讯线路定位或重定位到建筑物的不同部分,以便能更容易地管理通信线路。使在移动终端设备时能方便地进行插拔。 配线间是各管理子系统的安装场所。 风采酒店的配线间以多层共用一个配线间的方式分布,用于将连接至工作区的水平线缆与自主配线间引出的垂直线缆相连接。 对于信息点不是很多,使用功能又近似的楼层,为便于管理,可共用一个子配线间;对于信息点较多的楼层应在该层设立配线室。配线室的位置可选在距弱电竖井旁附近的房间内。配线室用于安装插座架和安装计算机网络通讯设备。本项目中,我们根据贵方的实际情况,在第一楼设主配线间和第十楼设分配线室。 配线间安装说明: 干缆水平线缆 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
推荐的分配线间安装示意图 根据风采酒店的实际实际情况: 在本方案中使用墙装式光纤接续装置,它将从主配线间引出的光缆引入,通过光纤跳线与网络设备相连,由网络设备上的UTP端口经UTP跳线与 插座架(置于19英寸机柜中)相连。 光纤配线架(或配线箱),置于各分中心的配线间内。其上嵌耦合器安装板,共有8个SC连接器安装孔,光纤接头是SC型,此接头由陶瓷材料制成,最大信号衰减量小于,斜闩卡口式SC藕合器(C2000A-2),可用作 所有电话系统均可采用50对110配线架组件。 电话系统的水平部分设计采用了超五类UTP双绞线,管理子系统采用了上列110安装架,可实行方便的跳接。 配线间的设计 设备子系统(主配线间)由设备间中的电缆、连接器和相关支撑硬件组成,它把各种不同设备互连起来。该子系统将布线交叉处与公共系统设备(如Hub等)连接起来。 配线间环境的要求 按照标准的设计要求,设备间尤其是要集中放设备的设备间,应尽量 满足下面的要求: 将设备间尽可能安排在服务电梯附近,以便装运笨重的设备;室温应保持在18℃至27℃之间,相对湿度保持在30%—55%;保持室内无尘或少尘,通风良好,亮度至少达30英尺—烛光; 安装合适的消防系统(如采用湿型消防系统,不要把喷头直接对准电气设 备);使用防火门,至少能耐火1小时的防火墙和阻燃漆;提供合适的门至少要有一扇窗口留作安全出口;尽量远离存放危险物品的场所和电磁干扰源(如发射机和电动机);设备间的地板负重能力至少应为500kg/平方米。 系统中典型的接线间,其可以走进人的最小安全尺寸是120X150cm, 标准的天花板高度为240cm,门的大小至少为高宽1M,向外开。在主 、分配线间,最好有供放置设备的设备柜,其大小可按设备的尺寸而定,一般采用木质或玻璃材料制成。在设备间尽量将设备柜放在靠近竖井的位置,在柜子上方应装有通风鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
口用于设备通风。 在配线间内应至少留有二个为本系统专用的,符合一般办公室照明要求的220V电压,电流10A单相三极电源插座。如果需要在配线间内放置网络设备,则还应根据接线间内放置设备的供电需求,配有另外的带4个AC双排插座的20A专用线路。此线路不应与其他大型设备并联,并且最好先连接 到UPS,以确保对设备的供电及电源的质量。 配线架的选型与安装: 电脑的主配线间设在凯悦酒店一楼的中心监控室内。主配线间内使用8孔光缆配线架,用来端接来自各分配线间的光缆,并通过光纤跳线和计算机网络中心交换机相连。直接安装在标准的19"机柜内,用于主 干光纤和网络设备的连接,十分易于管理。 表3 管理子系统材料估算表 名称 主配线间 分配线间 24口配线架 2 5 机 柜 1 1 110配线架 8 10 总投资估算 一:材料费共计: 施 工 费:材料费×15% 测 试 费:免 售后服务费:免 材料运费:免 总投资共计: 玖万壹仟柒佰肆元整(人民币) 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
六. 综合布线系统测试手段方法和标准 测试原因 本项目所用布线产品均为满足国际标准并通过了ISO9001及UL验证,但因设计和实施过程中又加入了很多人为因素,必 须对整个布线系统在诸如连接正确性,接续性,短路,开路,信号衰减,近端串 扰(NEXT),突发性干扰,计算机网络的连通性,误码率及性能等方面产生很大的影响。计算机网络安装时,所产生的错误有60%是缆线和接插件安装问题。因 此,在工程完工后,有必要在诸方面对整个系统进行全面测试,以向贵单位证明 缆线系统的安装是合格的。所有测试程序均遵循国际标准TIA/EIA TSB-67进行。 测试模型 对缆线系统的测试应是联合测试,而不是指对某一个或某几个部件的测试,测试通路应为真正的应用环境,以下为综合布线系统测试的二种标准测试模型。 Horizontal CablePatch PanelOutletTest Equipment CordsStart ofEnd ofbasic linkbasic linkTesterTesterRemote 基本链路测试模型 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
User抯 P捨 慴???Horizontal CableOutletCross ConnectUser抯 ?灭煵? ?湴????扬Start of End ofchannelchannelTesterTesterRemote 信道测试模型 双绞线系统的测试内容 双绞线端接线图测试 线缆长度测试 衰减测试 近端串扰测试 连接正确性测试 所有连接完好的信息点连接的正确性要保证100%;必须保证所有信息点无短路现象、开路现象、线对绕接现象、线对反接现象。 双绞线系统中,水平子系统的4对非屏蔽/屏蔽双绞线(UTP/FTP)的连接都 是按标准来进行的,在配线架一端都按以下方式来连接。 第一对:兰白 兰 第二对:桔白 桔 第三对:绿白 绿 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
第四对:棕白 棕 而对信息插座的连接,则是按几种标准来实现的,即4对双绞线可按586A、586B、USOC等标准实现连接 。如下图所示: 第?对 第?对 第?对 第?对 1 2 3 4 5 6 7 8 5 68 A 线对号 线芯号 1 T1 5 R1 4 2 T2 3 R2 6 3 T3 1 R3 2 4 T4 7 R4 8 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
第二对 第四对 第1对 第三对 1 2 3 4 5 6 7 8 568B 线对号 线芯号 1 T1 5 R1 4 2 T2 1 R2 2 3 T3 3 R3 6 4 T4 7 R4 8 第四对第三对第二对第一对1 2 3 4 5 6 7 8 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
USCO 线对号 线芯号 1 T1 5 R1 4 2 T2 3 R2 6 3 T3 2 R3 7 4 T4 1 R4 8 不过一般采用EIA/TIA586B连接方式,本次实施中,使用586B方式连接。由于在实施过程中,要分别对众多水平双绞线的两端实现终接,这就有可能造成终 接顺序不正确,同时也可能在终接时造成短路或开路 。 而在穿线施工过程中,负责穿线施工的单位,可能因用力过大或不正确的穿线方法或用金属管/线槽之边沿的锋刃,将缆线全部或部分割断、拉断而造成缆线开路,也即缆线不能连续。 测试仪器:FLUKE DSP4000,其中一台是主机,另一台为远端。 测试方法:先选定测试模型-是链路测试还是信道测试,然后按所选模型的模式 端测试仪。 测试结果:所有连接完好的信息点连接的正确性要保证100%;必须保证所有信息点无短路现象、开路现象、线对绕接现象、线对反接现象。 垂直子系统中,缆线的连接正确性是由色码得到保证的,色码编排如下: 线对号 端部 环箍 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
1-5 白(W) 蓝 (BL) 6-10 红 (R) 橙 (O) 11-15 黑 (BK) 绿 (G) 16-20 黄 (Y) 棕 (BR) 21-25 紫 (V) 灰 (S) 按顺序组合,如1-5对线则有:蓝白、蓝为第一对线;橙白、橙为第二对线;绿白、绿为第三对线;棕白、棕为第四对线;灰白、灰为第五对线,其它依次 类推。安装终接按这些顺序按此色标进行,方可保证连接的正确性。 对于垂直子系统中所用的多芯双绞线之测试,则使用如下的测试手段 : 测试仪器:暂定FLUKE DSP4000缆线测试仪; 测试方法:一端接FLUKE DSP4000缆线测试仪,另一端接 Loopback; 测试结果:任何一根线的连接正确性为100%;无任何短路、开路、绕接、错接现象。 线缆长度测试 在双绞线测试中基本链路Basic Link测试水平布线长度不能超过94M(含两个二米测试跳线)。信道Channel测试长度不大于99米(含三条三米跳线)。 衰减测试 衰减为信号在传输介质上进行传输的过程中所产生的损耗。 测试对象:超五类联合测试 测试条件:对超五类线及相关产品实现从-100MHZ的测试,测试温度为20摄 氏度-30摄氏度;信息点到配线间距离不超过90米。 测试仪器:(仪器选用如上所述) 测试方法:被测线路一端按仪器;另一端接loopback;仪器的显示器上将显示测试结果 或结论,一般显示通过或不通过。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
测试结果:显示的测试结果应 满足第一章中质保证书中的性能参数。 对垂直子系统中的多芯双绞线之衰减测试,其结果不大于下表所示的值视为通过。 测试频率 衰减值 (MHZ) (db/100M) 1 4 8 10 16 100 近端串扰测试 近端串扰本身对终接点(跳线架、信息插座)处的非双绞金属介质很敏感,同时,对 粗劣的安装也非常敏感。例如在终接点处的不绞的线长度至多不能超过13mm(对五类 线而言),或25mm(对四类线而言)等。因此,对NEXT的测试相当 重要。 NEXT(dB)=20log10 Vn/Vi Vi输入值(也是正常电压值),Vn是所产生的干扰信号,因为Vn<Vi, 那么下面表中出现的NEXT值实为负数。 测试对象:超五类产品的联合测试 测试条件:对超五类线及相关产品实现从--100MHZ的测试, 测试温度为20 度至30度信息点到配线架距离不超过90米。 测试结果:测试结果将显示在仪器上,一般是显示通过或不通过。显示的测试结鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
果应 满足第一章中质保证书中的性能参数。 光缆系统的测试 由于光缆系统的实施过程中,涉及到光缆的铺设,光缆的弯曲半径,光纤的熔接,跳线,更由于设计方法及物理布线结构的不同,导致两网络设备间的光纤路径 上光信号的传输衰减有很大不同。 根据标准规定和设计方法,则应充分保证任两段已终接好的光缆中的光纤,连同跳线与连接线一起,总的衰应在10db (850nm)之内。 测试条件:熔接之后的光缆连同跳线的综合测试;被测光纤规格微米/125微米 多模光纤;测试波长:1300nm和850nm。 测试结果:对任一段熔接好的光纤数据通路,其水平链路衰减值限制如下: < 2dB: 1300nm < 2dB: 850nm 这佯才能绝对保证任两段光纤连起来,总的衰减值小于 9dB(1300nm)或10dB(850nm)。 七. 技术服务 凯悦酒店结构化布线工程在设计与施工过程中,会形成各种设计文档与测试记录,为保证设工与设计的完整性,我们向甲方提供如下的文档: 1、布线系管理文档 2、完工测试 3、竣工文档 4、施工责任与质量保证 上述资料为用户提供了使用本布线系统完整的资料,为用户将来安装网络系统提供可靠的技术保证。 布线系统管理文档 为用户提供本系统的未来管理资料,我们提供的布线系统文档包括: ·《布线系统各层平面图》 可用于查信息点的分布位置,槽道的路线。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
·《布线系统系统图》 用于查各级配线架、水平电缆、垂直电缆的连接关系,水平子系统、配线架和主干电缆的器件数量、种类等。 ·《信息点房间号表》 用于查信息点所在的房间号,可贴在主配线箱上,查找方便。 ·《配线架电缆卡接位置图》 用于查找配线架各位置上卡接的电缆所对应的信息点编号,此图与 配线架标签上的标号是一致的。配线架上卡接的水平电缆一般不会改动,所以此表一般不会改动;但如果信息点有增加,则此表要更新。 ·《信息点跳线路径表》 这是布线系统中要经常更新的文档,每次跳线修改活动都要仔细记录在此表上,此表更新不及时必将导致布线系统的混乱。如果已造成了混乱则要进行全面的测试,重新生成此文档。 ·《布线系统维护记录》 用来记录所有的维护操作,以备查对,用户应养成忠实详细记录维护活动的习惯,出现问题时记录将非常有助于查对失误的操作,以追踪和修改错误。 完工测试 施工完成后,我们对系统进行两种测试。 线路测试 采用专用的五类电缆测试仪对TIA568所规定的布线系统的各项技术指标进行测试,包括所有信息点的接线图,长度干扰,衰减量等指标。 联机测试 选取若干个工作站进行实际的联网测试。 测试标准 双绞线连接:根据ISO/11801标准Class D ()之要求制定。 测试人员: 受过 TCL综合布线系统培训并持有证书的测试工程师。 竣工文档 在竣工时作为整个工程的结尾,我们将向甲方提供如下文档: 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
线路测试报告 这是由电缆测试仪生成的测试报告,传到计算机后整理出来的。 布线系统管理文档。 布线系统竣工平面图。 施工责任与质量保证 此工程中,我公司的责任是: 1、布线系统的详细设计; 2、施工穿线; 4、提供布线系统器件,包括插座暗盒、电缆和各种插接件; 5、信息插座、配线架的安装; 6、整个系统包括光缆的测试。 为保证施工质量,我们除进行工程过程中的经常性的施工督导外,还将进行两次阶段性的检查表格逐个指标的检查: 穿线前检查 包括钢管、线槽、插座铁盒和配线箱的安装情况的检查。 穿线检查 包括穿线的数量、路径、编号的检查。 以上检查均按TCL布线施工要求执行。 八. 公司简介 广州嘉伦通信科技有限公司是综合布线的开发、省场销售、为政府机关、企业、银行、学校、智能社区等提供模块化开放式综合布线系统,提供包括综合布线、网络设备设备等性能优良的端到端网络解决方案。广州嘉伦通信科技有限公司集中了通信介入领域的综合产业的优势,为用户提供了超五类系列产品、六类产品系列,以及光网络解决方案,努力实现“综合鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
布线,连接美好新生活”的品牌愿望。综合布线系统在广州本田、燕塘集团、国际香料、农垦集团、中国人寿保险、信诚人寿保险、太平人寿保险、广东电视台、珠江电视台、南方电视台、亚洲国际大酒店、皇家国际饭店、新天河宾馆、广之旅、羊城之旅、广州军区、南方医院、广州第一军医大学、五山高校、九易广告公司、华展国际货运、锡安人才中心、网域科技、朝日科技、迪莱贸易、神通期货、三九智慧、创博人才中心、宁夏嘉信证券、鸿联九五、威加威汽车精品、科学城……等大型项目的布线及网络工程。 在本次综合布线系统方案设计过程中,本公司基于认真、严谨、求实的精神,并根据以往几年里在大型综合布线系统的项目中不断积累的在项目管理、方案设计、现场施工管理、工程施工各方面经验,力争以最优的方案、最好的服务来达到全方位在项目实施中对客户承诺。 在售后服务方面,我公司以雄厚的技术实力及丰富工程经验以及大型网络设计及集成经验,及为贵方的经济效益方面着想,推出一整套完整的售后服务计划使贵方在今后的系统管理过程中能不断的得到我公司在各方面的支持。 九. 服务与质保 我们深知用户从布线到网络建设的规划和要求。给用户提供了一个基础建设,高层应用的全套网络解决方案。因此我们的服务不但是为客户建设好一个先进而高质量的高速信息通道,而且今后我们有能力有责任协助您建设好一个网络平台。 多年的工作经验,使我们深知,标准、开发、高质量的布线工程对一栋大楼的建设起着重要的作用。而质量的保证是一种技术及公司实力的体现,而非一般工程公司口头承诺,对我公司所完成的布线工程项目,我公司为您直接提供优质服务3年的质保。 十. 配套设计要求 一、接地设计采用计算机单独接地。多点共用一条接地线,要求大楼接地电阻值不宜大于1Ω。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗
多个接地点 多个接地点 多个接地点 多个接地点 ?? 接线排 接地电极 二、PDS的接地考虑: 主要办公区以及计算机主机房,都应提供合适的接地端。建筑物入口处的接地端,应用直径4mm铜线把入口电缆屏蔽层以及保护器接地片焊接在一起。在网络接口处,接地线焊到终端处。干线电缆的位置应在网络接口处,接地线焊到终端处。 凡于结构化布线系统有关的有源设备的正极或外壳,干线屏蔽电缆层及连通地线均应接地。使整个大楼的接地系统组成一个笼式均压体。 要求风采酒店的接地电阻值不宜大于1Ω,当楼内设备有更高要求时,或邻近有强电磁场干扰,而对接地电阻有更高要求时,应取其中的最小值作为设计依据。 鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗鞗